Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(3)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(6)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(1)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(3)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(6)
Mitsubishi Heavy Industries
(1)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
SUZ-M35VA/SFZ-M35VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SFZ-M35VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
AC035BXAPKG/AC035BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.13 | -25° | 3.50 | 2.00 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOHG14KVCA/AGHG14KVCA
AGH**K
|
GENERAL | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
ROG14KVCA/RGG14KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOEG14KVCA/AGEG14KVCA
AGE**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOEG14KVCA/AGYG14KVCA
AGY**K
|
FUJITSU | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOYG14KVCA/AGYG14KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
RAC-35NPE / RAI-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
RAC-35NPE / RAD-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
MFZ-KW35VG/MUFZ-KW35VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
AOYG12KVCA/AGYG12KVCA
AGY**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOHG12KVCA/AGHG12KVCA
AGH**K
|
GENERAL | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
ROG12KVCA/RGG12KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOEG12KVCA/AGEG12KVCA
AGE**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOEG12KVCA/AGYG12KVCA
AGY**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOYG12KVCA/AGYG12KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
SUZ-M35VA/MFZ-KT35VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.41 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MFZ-KT35VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.41 | -10° | 3.50 | 2.60 | |
|
SRC35ZS-W2/SRF35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.70 | 4.02 | -10° | 3.50 | 2.90 | |
|
RXM35R9 / FVXM35A9
RXM
|
DAIKIN | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.11 | 4.63 | 3.90 | -15° | 3.40 | 2.80 | |
|
RXM35A9 / FVXM35B
RXM
|
DAIKIN | Floor standing | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.19 | 4.68 | 3.91 | -20° | 3.40 | 2.80 | |
|
RXTM30A / FVXTM30B
RXTM
|
DAIKIN | Floor standing | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.75 | 4.44 | -30° | 3.00 | 3.00 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 |