Filters · 3 active
Manufacturer:
AIRWELL
FUJI ELECTRIC
AIRCLASS
(1)
ATLANTIC
(10)
AUX
(16)
BOSCH
(42)
BRYANT
(2)
Buderus
(11)
CARRIER
(33)
CIAT
(9)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(122)
EQUATION
(1)
FUJITSU
(93)
Fujitsu Atlantic
(50)
GENERAL
(71)
GREE
(29)
GSS
(1)
HAIER
(117)
HEC
(3)
HEIWA
(2)
HISENSE
(94)
HITACHI
(22)
IVT
(4)
Inventor
(29)
KAYSUN
(10)
LG
(66)
MIDEA
(181)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(23)
NORD
(15)
Nobu
(2)
PANASONIC
(66)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(45)
THERMOR
(18)
TOSHIBA
(46)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(6)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ROG12KGCA/RSG12KGTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
ROH12KGCG/RSH12KGTG
RS**K
|
FUJI ELECTRIC | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
ROG12KGCB/RSG12KGTF
RS**K
|
FUJI ELECTRIC | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
ROG14KBTA2/RSG07KGTB/RSG07KGTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 4.63 | -15° | 4.00 | 3.50 | |
|
ROH14KGCG/RSH14KGTG
RS**K
|
FUJI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -15° | 4.20 | 4.00 | |
|
DDMD-035N-09M25/YDAX-035H-09M25**
DDMD
|
AIRWELL | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
ROG12KBTB/RDG12KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.10 | -15° | 3.50 | 3.40 | |
|
ROG14KBTB/RCG14KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
ROG14KGCA/RSG14KGTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
ROG12KBTB/RCG12KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG14KGCB/RSG14KGTF
RS**K
|
FUJI ELECTRIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
ROH12KMCG/RSH12KMCG
RS**K
|
FUJI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 3.92 | -15° | 3.40 | 2.50 | |
|
ROH12KMCG/RSH12KMCG-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 3.92 | -15° | 3.40 | 2.50 | |
|
HDHC-035N-09M25/YDAC-035R-09M25
HDH
|
AIRWELL | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
HDMB-035N-09M22-GY/YDAB-035H-09M22
Harmonia
|
AIRWELL | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
HDMB-035N-09M22/YDAB-035H-09M22
Harmonia
|
AIRWELL | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
HDMB-035N-09M22-MR/YDAB-035H-09M22
Harmonia
|
AIRWELL | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
HDMC-035N-09M25/YDA*-035*-09M25
Harmonia
|
AIRWELL | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
HDMC-035N-09M25-BK/YDAC-035R-09M25**
Harmonia
|
AIRWELL | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
CDMD-035N-09M25/YDAX-035H-09M25**
CDMD
|
AIRWELL | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
ROG14KBTB/RDG14KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
ROG12KVCA/RGG12KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
ROG12KMCC/RSG12KMCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA /RSG12KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA /RSG12KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KMCC/RSG12KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KETA/RSG12KETF-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
ROG12KBTB/RDG12KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROH14KMCG/RSH14KMCG
RS**K
|
FUJI ELECTRIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROH14KMCG/RSH14KMCG-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROH12KNCA/RSH12KNCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
AW-YXDL012-H91/AW-XDL012-N91
XDL
|
AIRWELL | Console | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
YDAF-035R-09M25/XDLF-035N-09M25
XDLF
|
AIRWELL | Console | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
ROG14KETA /RSG14KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA /RSG14KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETE
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETE-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KMCC/RSG14KMCF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETF
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KETA/RSG14KETF-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
ROG14KVCA/RGG14KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
ROH12KLTA/RSH12KLTA
RS**K
|
FUJI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
ROG14KBTB/RDG14KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
XDMX-035N-09M25/YDAX-035H-09M25
XDMX
|
AIRWELL | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
ROG14KATA/RCG14KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
ZDAA-2040-09M25/HDHC-025N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
ROG12KATA/RCG12KVLA
RCG**K
|