Filters · 9 active
Manufacturer:
AIRCLASS
BOSCH
COLIBRI
Candy
DAIKIN
Inventor
WESTPOINT
YORK
AIRWELL
(22)
ATLANTIC
(10)
AUX
(42)
BRYANT
(1)
Buderus
(10)
CARRIER
(33)
CIAT
(10)
CONFORT AIR
(1)
DE DIETRICH
(6)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(29)
GSS
(1)
HAIER
(107)
HEC
(1)
HEIWA
(2)
HISENSE
(92)
HITACHI
(34)
IVT
(3)
KAYSUN
(10)
LG
(63)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
PITSOS
(1)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
XTRON
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(2)-18/LN2UVI-09WFI+LN2UVI-09WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 5.30 | 4.34 | |
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
RXM50A8 / FFA50A9
RXM
|
DAIKIN | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.86 | 3.36 | -15° | 5.00 | 3.84 | |
|
RXM50A9 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.92 | 3.86 | 3.35 | -10° | 5.00 | 4.35 | |
|
CY-18RBW-IN/CY-18RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
RXM50R / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RXM50A / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
U6RSL(2)-18/AR5VI-09WiFi+AR5VI-09WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL5000M 53/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CY-18QBIN-A/CY-18QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
PFZUVO-18/PFZUVI-18WIFI
Professional Z
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
CY-18RAIN-A/CY-18RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.71 | -10° | 4.80 | 3.60 | |
|
YHKF18YEEGXFO-X/YHKF18XEEGXF-RX
Altair YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.71 | -10° | 5.10 | 3.30 | |
|
FUTO-18/FUTI-18WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
RXM50A8 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.84 | 3.82 | 3.23 | -15° | 5.00 | 4.35 | |
|
RXM50R / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
CL5000M 53/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
RXM50A8 / FDXM50F9
RXM
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.89 | 2.99 | -15° | 5.00 | 4.00 | |
|
RZAG50B / FDXM50F9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
RZAG50B / FNA50A9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
RXM50A9 / FDXM50F9
RXM
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -10° | 5.00 | 4.00 | |
|
U7RS-18/V7LI-18WiFiR
Console R32
|
Inventor | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
RXM60R / FFA60A9
RXM
|
DAIKIN | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.76 | 4.04 | 3.41 | -15° | 5.70 | 3.96 | |
|
YHKF18XEEBMH-RY / YHKF18YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.65 | -10° | 5.30 | 4.10 | |
|
RXM60R / FHA60A9
RXM
|
DAIKIN | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.08 | 3.87 | 3.32 | -15° | 5.70 | 4.71 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
U7RS-18/V7CRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
YUKF18BYEEBMO-1/YKKF18BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
RXM50R / FDXM50F9
RXM
|
DAIKIN | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -15° | 5.00 | 4.00 | |
|
RXM50A / FDXM50F9
RXM
|
DAIKIN | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -15° | 5.00 | 4.00 | |
|
RZAG50B / FFA50A9
RZAG
|
DAIKIN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.01 | 3.10 | -10° | 5.00 | 4.30 | |
|
ARXM50R / ADEA50A
ARXM
|
DAIKIN | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.65 | 4.00 | 3.74 | -15° | 5.00 | 4.40 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
O3MVO32-18B/O3MVI32-18WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-X/YHKF18XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
L6VO32-18/L6VI32-18WF
Life PRO
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-T/YHKF18XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
RZAG50A / FDXM50F9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
RZAG50A / FNA50A9
RZAG
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -20° | 5.00 | 4.30 | |
|
ARXM60R / ADEA60A
ARXM
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.74 | 4.00 | 3.63 | -15° | 5.70 | 4.60 | |
|
2MXM50A / FDXM25F9 / FDXM25F9
2MXM
|
DAIKIN | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 3.78 | 3.66 | -15° | 5.00 | 4.20 | |
|
ARXF50A / ATXF50A
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.03 | 3.71 | -15° | 5.00 | 4.60 |