Filters · 3 active
Manufacturer:
AIRWELL
FUJITSU
AIRCLASS
(1)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
HDLS-050N-09M25/YDAS-050R-09M25
HDLS
|
AIRWELL | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
ZDAA-2050-09M25/HDHC-025N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AW-YXDL018-H91/AW-XDL018-N91
XDL
|
AIRWELL | Console | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.55 | -10° | 5.20 | 5.00 | |
|
YDAF-050R-09M25/XDLF-050N-09M25
XDLF
|
AIRWELL | Console | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.55 | -10° | 5.20 | 5.00 | |
|
XDMX-050N-09M25/YDAX-050H-09M25
XDMX
|
AIRWELL | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
HDMB-050N-09M22-MR/YDAB-050H-09M22
Harmonia
|
AIRWELL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.67 | -10° | 5.30 | 4.10 | |
|
HDMB-050N-09M22/YDAB-050H-09M22
Harmonia
|
AIRWELL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.67 | -10° | 5.30 | 4.10 | |
|
HDMB-050N-09M22-GY/YDAB-050H-09M22
Harmonia
|
AIRWELL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.67 | -10° | 5.30 | 4.10 | |
|
HDLE-050N-09M25/YDAE-050R-09M25
Aura V2
|
AIRWELL | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.90 | -10° | 4.60 | 3.70 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
HDLA-050N-09M25/YDAA-050H-09M25
Aura
|
AIRWELL | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
ZDAA-2050-09M25/XDMX-025N-09M25x2
ZDAA
|
AIRWELL | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
YDAM-050R-09M25/CDHM-050N-09M22
OASIS
|
AIRWELL | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
YDAM-050R-09M25/DDHM-050N-09M22
OASIS
|
AIRWELL | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.50 | |
|
AOYG18KATA/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
FDMX-050N-09M25/YDAX-050H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CDMD-050N-09M25/YDAX-050H-09M25**
CDMD
|
AIRWELL | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTB/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/AUXG18KVLA
AUY**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
AOEH18KACB2/ASEH09KLTBL/ASEH09KLTBL
AOE**K Multi
|
FUJITSU | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.30 | 3.73 | -15° | 5.00 | 3.50 | |
|
AOEH18KACB3/ASEH09KLTBL/ASEH09KLTBL
AOE**K Multi
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.20 | 3.80 | -15° | 5.00 | 4.30 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOEG18KLCA/ASEG18KLCA
ASE**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
HDHC-050N-09M25/YDAC-050R-09M25
HDH
|
AIRWELL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AOYG18KBTB/ARXG18KLLAP
ARY**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
YDAM-050R-09M25/FDHM-050N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.31 | 4.10 | 3.73 | -10° | 5.00 | 4.40 | |
|
DDMD-050N-09M25 /YDAX-050H-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
ZDAB-2050-09M25/HDHC-025N-09M25x2
ZDAB
|
AIRWELL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
AOYG18KBTB/AUXG18KRLB
AUY**K
|
FUJITSU | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
HDMC-050N-09M25/YDA*-050*-09M25
Harmonia
|
AIRWELL | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
HDMC-050N-09M25-BK/YDAC-050R-09M25**
Harmonia
|
AIRWELL | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 |