Filters · 4 active
Manufacturer:
AIRCLASS
Inventor
PANASONIC
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(2)-18/LN2UVI-09WFI+LN2UVI-09WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 5.30 | 4.34 | |
|
CU-3TZ52TBE/CS-TZ25ZKEW/CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.82 | -15° | 5.20 | 4.80 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
U6RSL(2)-18/AR5VI-09WiFi+AR5VI-09WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.30 | |
|
PFZUVO-18/PFZUVI-18WIFI
Professional Z
|
Inventor | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
FUTO-18/FUTI-18WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
U7RS-18/V7LI-18WiFiR
Console R32
|
Inventor | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
U7RS-18/V7CRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
O3MVO32-18B/O3MVI32-18WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
L6VO32-18/L6VI32-18WF
Life PRO
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CU-3TZ52CBE/CS-TZ42CKEW/CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.60 | -15° | 5.20 | 4.80 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CU-BZ50XKE / CS-BZ50XKE
2022
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 4.70 | 4.00 | |
|
CU-UZ50WKE / CS-UZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-FZ50WKE / CS-FZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-UZ50ZKE / CS-UZ50ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-UZ50CKE / CS-UZ50CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
AR5VO-18/AR5VI-18WFI
Aria (AR5)
|
Inventor | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.70 | -10° | 5.30 | 4.10 | |
|
Ν2UVO-18/Ν2UVI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N2VOCP-18/Ν2VICP-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
NPVO-18/NPVI-18WFI
Neo Plus
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N3VO-18/N3VI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
VERO-18/VERI-18WFI
Vero
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CU-BZ50ZKE / CS-BZ50ZKE
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-BZ50CKE / CS-BZ50CKE
2025
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
U7RS-18/V7iCRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
NRO-18/NRI-18WFI
Nura
|
Inventor | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 3.90 | -10° | 5.20 | 4.10 | |
|
CU-3Z52CBE / CS-Z42CKEW / CS-Z42CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.12 | -15° | 5.20 | 5.20 | |
|
CU-2TZ50TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.35 | -15° | 5.00 | 4.50 | |
|
CU-RZ50WKE / CS-RZ50WKEW
2019
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50ZKE / CS-RZ50ZKEW
2023
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50CKE / CS-RZ50CKEW
2025
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UD3EAW
2017
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
U7RS-18/V7DI-18WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UFEAW
2018
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-Z50CBEA / CS-Z50CFEAW
2025
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-2TZ50CBE/CS-TZ25CKEW/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 3.97 | -15° | 5.00 | 4.20 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
U-50PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
LEUVO-18/LEUVI-18WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 |