Filters · 3 active
Manufacturer:
PANASONIC
TOSHIBA
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM561ATP-E1/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 4.00 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GM562ATP-E/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 4.01 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GV561ATP-E/RAV-HM561KRTP-E
DIC
|
TOSHIBA | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.90 | 3.53 | -15° | 5.00 | 2.80 | |
|
CU-3TZ52TBE/CS-TZ25ZKEW/CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.82 | -15° | 5.20 | 4.80 | |
|
RAV-GM561ATP-E1/RAV-HM561KRTP-E
DI
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.31 | 4.00 | 3.42 | -15° | 5.00 | 2.80 | |
|
RAS-18B2AVG-E2/RAS-B18B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18LAV2G-E/RAS-B18LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAV-GV561ATP-E/RAV-HM561BTP-E
DIC
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 3.21 | -15° | 5.00 | 2.80 | |
|
RAV-GM562ATP-E/RAV-HM561KRTR-E
DI
|
TOSHIBA | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.69 | 4.02 | 3.42 | -15° | 5.00 | 2.80 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
CU-3TZ52CBE/CS-TZ42CKEW/CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.60 | -15° | 5.20 | 4.80 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
CU-BZ50XKE / CS-BZ50XKE
2022
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 4.70 | 4.00 | |
|
CU-UZ50WKE / CS-UZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-FZ50WKE / CS-FZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-UZ50ZKE / CS-UZ50ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
CU-UZ50CKE / CS-UZ50CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
CU-BZ50ZKE / CS-BZ50ZKE
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-BZ50CKE / CS-BZ50CKE
2025
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
RAV-GM561ATP-E1/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.61 | 4.32 | 3.90 | -15° | 5.00 | 2.80 | |
|
RAV-GM562ATP-E/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.34 | 3.90 | -15° | 5.00 | 2.80 | |
|
RAV-GV561ATP-E/RAV-HM561UTP-E
DIC
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.79 | -15° | 5.00 | 2.80 | |
|
CU-3Z52CBE / CS-Z42CKEW / CS-Z42CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.12 | -15° | 5.20 | 5.20 | |
|
CU-2TZ50TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.35 | -15° | 5.00 | 4.50 | |
|
CU-RZ50WKE / CS-RZ50WKEW
2019
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50ZKE / CS-RZ50ZKEW
2023
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50CKE / CS-RZ50CKEW
2025
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UD3EAW
2017
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
RAV-GM561ATP-E1/RAV-HM561MUTP-E
DI
|
TOSHIBA | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.37 | 3.61 | -15° | 5.00 | 2.80 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 | |
|
RAS-18E2AVG-E/RAS-B18S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.60 | -15° | 5.00 | 3.80 | |
|
RAS-18E2AVG-E/RAS-B18E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.60 | -15° | 5.00 | 3.80 | |
|
RAS-18CAVG-E/RAS-B18CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.60 | -15° | 5.00 | 3.80 | |
|
RAV-GM562ATP-E/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.11 | 3.27 | -15° | 5.00 | 2.80 | |
|
CU-Z50UBEA / CS-Z50UFEAW
2018
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-Z50CBEA / CS-Z50CFEAW
2025
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-2TZ50CBE/CS-TZ25CKEW/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 3.97 | -15° | 5.00 | 4.20 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
RAV-GM562ATP-E/RAV-HM561MUTP-E
DI
|
TOSHIBA | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.40 | 3.61 | -15° | 5.00 | 2.80 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 |