Filters · 5 active
Manufacturer:
BOSCH
Inventor
SAMSUNG
THERMOR
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
U6RSL(2)-18/LN2UVI-09WFI+LN2UVI-09WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 5.30 | 4.34 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
U6RSL(2)-18/AR5VI-09WiFi+AR5VI-09WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.30 | |
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
NISEKO MURALE IM42-NS / E1U42L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
PFZUVO-18/PFZUVI-18WIFI
Professional Z
|
Inventor | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
CL5000M 53/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
NISEKO MURALE IM52-NS / E1U52L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
FUTO-18/FUTI-18WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
CL5000M 53/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
AC052RXADKG/AC052TNXDKG
CAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.90 | 3.43 | -20° | 5.00 | 2.40 | |
|
AR70F18C1DBN/AR70F18C1DBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80F18CAAWN/AR80F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80H18CAAWN/AR80H18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR70H18CACBN/AR70H18CACBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
U7RS-18/V7LI-18WiFiR
Console R32
|
Inventor | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
IM35V2-NG + IM35V2-NG/E2U50LV2-NG-NS
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 5.00 | 4.70 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
U7RS-18/V7CRI-18WiFiR
Cassette R32
|
Inventor | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
AR18BXHQASIN / AR18BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -10° | 5.30 | 4.20 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
O3MVO32-18B/O3MVI32-18WiFiR
Omnia 3 (ECO)
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
L6VO32-18/L6VI32-18WF
Life PRO
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
U7RS-18/V7KI-18WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
NAGANO MURALE PURE IM52V2-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V2-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V3-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V3-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0BMN/AR40F18C0BMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR5VO-18/AR5VI-18WFI
Aria (AR5)
|
Inventor | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.70 | -10° | 5.30 | 4.10 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
Ν2UVO-18/Ν2UVI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N2VOCP-18/Ν2VICP-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
NPVO-18/NPVI-18WFI
Neo Plus
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N3VO-18/N3VI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
VERO-18/VERI-18WFI
Vero
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AJ052TXJ3KG / AR70F09C1AW / AR70F09C1AW
FJM
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.03 | 3.63 | -10° | 5.00 | 4.91 |