Filters · 4 active
Manufacturer:
HITACHI
SAMSUNG
Vulcano
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
UE-E3CM 53/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
UE-E3CM 53/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
RPIL-2.0UNE1NH / RAS-2.0UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.40 | -15° | 5.28 | 4.80 | |
|
RAC-CJ50WHAE / RAK-CJ50PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -15° | 4.60 | 4.35 | |
|
AC052RXADKG/AC052TNXDKG
CAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.90 | 3.43 | -20° | 5.00 | 2.40 | |
|
AR70F18C1DBN/AR70F18C1DBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80F18CAAWN/AR80F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80H18CAAWN/AR80H18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR70H18CACBN/AR70H18CACBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
RAS-2HVRC3 / RPK-2.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.88 | 3.91 | -25° | 5.00 | 5.00 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
AR18BXHQASIN / AR18BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -10° | 5.30 | 4.20 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
RAS-2HVRC3 / RCIM-2.0FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.57 | 3.81 | 3.85 | -25° | 5.00 | 5.00 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0BMN/AR40F18C0BMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
RAS-2.5HVRC3 / RPK-2.5FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.04 | 3.94 | 3.71 | -25° | 5.60 | 5.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AJ052TXJ3KG / AR70F09C1AW / AR70F09C1AW
FJM
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.03 | 3.63 | -10° | 5.00 | 4.91 | |
|
AR50F18C1AHN/AR50F18C1AHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR50F18C1BHN/AR50F18C1BHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
RAS-2.5HVRC3 / RCIM-2.5FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.86 | 3.71 | -25° | 5.60 | 5.20 | |
|
AR70F18C1AWN/AR70F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1AWN/AR60F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18CAAWN/AR60F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1KWN/AR60F18C1KWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18C1AWN/AR70H18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18CACWN/AR70H18CACWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
RAC-VJ50NHAE / RAD-VJ50RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.01 | 3.80 | -10° | 5.00 | 4.30 | |
|
AJ050HCJ2KG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.46 | 4.21 | 4.15 | -10° | 5.00 | 4.21 | |
|
RAC-VJ50NHAE / RAI-VJ50RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.11 | 3.72 | -10° | 5.00 | 4.30 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
RAC-50NPE / RAD-50RPE
RAC-NPE(D)
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.01 | 3.82 | -15° | 5.00 | 4.60 | |
|
RAC-DJ50WHAE / RAK-DJ50RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.50 | 3.71 | -15° | 5.00 | 4.35 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
RAM-E53N2HAE / RAK-DJ18RHAE / RAK-DJ35RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.21 | 3.90 | -15° | 5.30 | 4.80 | |
|
RAM-E53N3HAE / RAK-DJ18RHAE / RAK-DJ35RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.21 | 3.90 | -15° | 5.30 | 4.80 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RAC-VJ50WHAE / RAK-VJ50RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.60 | 3.85 | -15° | 5.00 | 4.35 | |
|
RAC-50NPE / RAI-50RPE
RAC-NPE(D)
|
HITACHI | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.84 | 4.37 | 3.82 | -15° | 5.00 | 4.30 | |
|
RAM-Y53N3HAE / RAK-XJ18QHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 3.99 | -10° | 5.30 | 5.60 | |
|
AC052BXAPKG/AC052BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -25° | 5.00 | 3.90 | |
|
RAS-2.5HVRC3 / RCI-2.5FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.53 | 4.18 | 4.12 | -25° | 5.60 | 5.20 |