Filters · 4 active
Manufacturer:
IVT
THERMOR
WESTPOINT
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
NISEKO MURALE IM42-NS / E1U42L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
NISEKO MURALE IM52-NS / E1U52L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
IM35V2-NG + IM35V2-NG/E2U50LV2-NG-NS
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 5.00 | 4.70 | |
|
NAGANO MURALE PURE IM52V2-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V2-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V3-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V3-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
Aero 605-1 O / Aero 605-1 I
Aero 600-1
|
IVT | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WIMO-18324.MH / WIM-18324.MH
WIM 324
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18326.MH / WIM-18326.MH
WIM 326
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18325.MH / WIM-18325.MH
WIM 325
|
WESTPOINT | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
Aero 705 O / Aero 705 I
Aero 700
|
IVT | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
Aero 705 O / Aero 705 IB
Aero 700
|
IVT | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 |