Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(6)
AUX
(4)
BOSCH
(8)
BRYANT
(0)
Buderus
(1)
CARRIER
(5)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(48)
EQUATION
(1)
FUJI ELECTRIC
(2)
FUJITSU
(8)
Fujitsu Atlantic
(3)
GENERAL
(5)
GREE
(8)
GSS
(0)
HAIER
(41)
HEC
(0)
HEIWA
(1)
HISENSE
(3)
HITACHI
(15)
IVT
(2)
Inventor
(4)
KAYSUN
(0)
LG
(5)
MIDEA
(11)
MITSUBISHI ELECTRIC
(30)
Mitsubishi Heavy Industries
(8)
NORD
(6)
Nobu
(0)
PANASONIC
(26)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(5)
THERMOR
(4)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS50XCAHRA/1U50KEFFRA-1
Expert electric heater
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.60 | 3.80 | 4.00 | -10° | 5.00 | 4.60 | |
|
AS50XCAHRA-MB/1U50KEFFRA-1
Expert electric heater
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.60 | 3.80 | 4.00 | -10° | 5.00 | 4.60 | |
|
AS50XCAHRA/1U50S2SJ2FA-2
Wall mounted - EXPERT
|
HAIER | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 4.00 | -10° | 5.00 | 4.60 | |
|
AS50XCAHRA-MB/1U50S2SJ2FA-2
Wall mounted - EXPERT
|
HAIER | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 4.00 | -10° | 5.00 | 4.60 | |
|
M3OA-18HFN8-Q/MSCB1BU-09HRFN8-QRD1GW+MSCB1BU-09HRFN8-QRD1GW
M3OA-18HFN8-Q
|
MIDEA | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.10 | -10° | 5.30 | 4.30 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
AS 018 JDB.UI/ 1U 018 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MB3/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-BH/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MW3/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-WH/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SJ1FA-3/1U50S2SJ2FA-2
Super Match mono-Jade
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V2-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V2-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MW3/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MB3/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
Virtus-18K-IN/Virtus-18K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V3-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V3-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
38QUS018D8S2-2/42QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.56 | 4.00 | 4.29 | -10° | 5.79 | 4.50 | |
|
GWHD(18)NK6OO GWH09YCXB-K6DNA2C/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.52 | -10° | 5.30 | 4.10 | |
|
AS 018 NBB.UI/1U 018 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.00 | -10° | 5.20 | 4.60 | |
|
AJ050HCJ2KG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.46 | 4.21 | 4.15 | -10° | 5.00 | 4.21 | |
|
GWH18AKCXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 4.00 | -10° | 5.30 | 4.20 | |
|
CU-3Z52CBE / CS-Z42CKEW / CS-Z42CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.12 | -15° | 5.20 | 5.20 | |
|
CU-2TZ50TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.35 | -15° | 5.00 | 4.50 | |
|
RM3U19 U24 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.26 | 4.22 | -10° | 5.27 | 4.50 | |
|
GWH18ACDXF-K6DNA1C
MONOSPLITS
|
GREE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.00 | -10° | 5.30 | 4.30 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
GWH18YDXF-K6DNA2Y
MONOSPLITS
|
GREE | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.20 | -10° | 5.30 | 4.30 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
MXZ-3F54VF4/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.16 | 4.11 | -15° | 5.30 | 4.60 | |
|
MXZ-3F54VF5/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.16 | 4.11 | -15° | 5.30 | 4.60 | |
|
RAV-GP561ATW-E/RAV-HM561KRTP-E
SDI
|
TOSHIBA | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.84 | 4.19 | 4.03 | -27° | 5.00 | 3.80 | |
|
U-50PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
RXJ50A / FTXJ50AB
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A / FTXJ50AS
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A / FTXJ50AW
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AS
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AB
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXJ50A9 / FTXJ50AW
RXJ
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXA50B8 / FTXA50CW
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 | |
|
RXA50B8 / FTXA50CB
RXA
|
DAIKIN | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.60 | 4.00 | -10° | 5.00 | 4.00 |