Filters · 3 active
Manufacturer:
BOSCH
Mitsubishi Heavy Industries
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
SRC60ZSX-W3/FDT60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.00 | 4.29 | -20° | 5.60 | 5.20 | |
|
SRC50ZSX-W3/FDT50VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.93 | 4.63 | 4.12 | -20° | 5.00 | 4.00 | |
|
SCM45ZS-W/SRK20ZSX-W/SRK25ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 4.70 | 5.00 | -15° | 4.50 | 4.10 | |
|
SCM50ZS-W/SRK25ZSX-W/SRK25ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 5.17 | -10° | 5.00 | 4.80 | |
|
SRC60ZSX-W3/FDE60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.72 | 4.41 | 3.60 | -20° | 5.60 | 4.50 | |
|
SRC60ZSX-W3/FDUM60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.37 | 3.83 | -20° | 5.60 | 4.70 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
SRC50ZSX-W3/SRK50ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.70 | 4.41 | -10° | 5.00 | 4.50 | |
|
SRC50ZSX-W3/SRK50ZSX-WF
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.70 | 4.41 | -10° | 5.00 | 4.50 | |
|
SRC50ZSX-W3/SRK50ZSX-WFB
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.70 | 4.41 | -10° | 5.00 | 4.50 | |
|
SRC50ZSX-W3/SRK50ZSX-WFT
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.70 | 4.41 | -10° | 5.00 | 4.50 | |
|
SRC50ZT-W/SRC50ZT-WF
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.92 | -10° | 5.00 | 4.80 | |
|
SRC50ZT-W/SRC50ZT-WFB
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.92 | -10° | 5.00 | 4.80 | |
|
SRC50ZT-W/SRC50ZT-WFT
ZT-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.92 | -10° | 5.00 | 4.80 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
SRC50ZSX-W3/SRF50ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 5.00 | 4.10 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
SRC60ZSX-W3/SRR60ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.30 | 3.54 | -10° | 5.60 | 5.20 | |
|
CL7000M 53/2 E /CL5000iU W 26 E +CL5000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL4000iU W 26 E +CL4000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
SRC50ZSX-W3/FDTC50VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.30 | 3.53 | -20° | 5.00 | 4.30 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
SRC50ZS-W/SRK50ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
SRC60ZSX-W3/FDTC60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.45 | 4.10 | 3.13 | -20° | 5.60 | 5.10 | |
|
CL6102i 55 HE / CL6102i W 55 HE
Climate 6102i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
SRC50ZSX-W3/FDE50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.07 | 3.70 | -20° | 5.00 | 3.80 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
SRC50ZTL-W/SRK50ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.58 | -10° | 5.00 | 4.00 | |
|
SRC45ZSP-W1/SRK45ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.68 | -10° | 4.50 | 3.80 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
SRC50ZSP-W1/SRK50ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.37 | -10° | 5.00 | 3.80 | |
|
SRC50ZSX-W3/FDUM50VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.89 | 3.39 | -20° | 5.00 | 3.70 |