Filters · 4 active
Manufacturer:
BOSCH
SAMSUNG
WESTPOINT
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.90 | 4.38 | -25° | 5.00 | 4.10 | |
|
AC052BXAPKG/AC052BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.58 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
AC052RXADKG/AC052RN4DKG
CAC
|
SAMSUNG | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.30 | 4.03 | -20° | 5.00 | 2.60 | |
|
AJ050TXJ2KG / AR70F09CAAW / AR70F09CAAW
FJM
|
SAMSUNG | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.54 | 4.64 | 4.38 | -10° | 5.00 | 4.21 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
AC052BXAPKG/AC052BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -25° | 5.00 | 3.90 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
WIMO-18325.MH / WIM-18325.MH
WIM 325
|
WESTPOINT | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL7000M 53/2 E /CL5000iU W 26 E +CL5000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL4000iU W 26 E +CL4000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
WIMO-18324.MH / WIM-18324.MH
WIM 324
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18326.MH / WIM-18326.MH
WIM 326
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
AJ050HCJ2KG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.46 | 4.21 | 4.15 | -10° | 5.00 | 4.21 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
CL6102i 55 HE / CL6102i W 55 HE
Climate 6102i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
AR70F18C1AWN/AR70F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1AWN/AR60F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18CAAWN/AR60F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1KWN/AR60F18C1KWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18C1AWN/AR70H18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18CACWN/AR70H18CACWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
AR50F18C1AHN/AR50F18C1AHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR50F18C1BHN/AR50F18C1BHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
AJ052TXJ3KG / AR70F09C1AW / AR70F09C1AW
FJM
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.03 | 3.63 | -10° | 5.00 | 4.91 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0BMN/AR40F18C0BMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 |