Filters · 3 active
Manufacturer:
FUJITSU
MIDEA
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEG18KBCA3/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTA2/ASYG09KGTB/ASYG09KGTB
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYG09KGTE/ASYG09KGTE
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOEG18KBCA2/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYH09KGTG/ASYH09KGTG
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
AOEH18KMTG/ASEH18KMTGL
ASE**K
|
FUJITSU | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOYG18KMTA/ASYG18KMTE
ASY**K
|
FUJITSU | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
AOEG18KMTA/ASEG18KMTE
ASE**K
|
FUJITSU | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.77 | 4.60 | 4.04 | -15° | 5.20 | 4.80 | |
|
MOX430-18HFN8-QRD6GW/MSOPBU-18HRFN8-QRD6GW
Oasis Plus
|
MIDEA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
M2OF-18HFN8-Q/MSOPBU-09HRFN8-QRE1GWV+MSOPBU-09HRFN8-QRE1GWV
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
MOX430-17HFN8-QRD6GW/MSOPBU-17HRFN8-QRD6GW
Oasis Plus
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.12 | -10° | 5.00 | 4.20 | |
|
MOX430-17HFN8-OPP/MSOPP-17HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.12 | -10° | 5.00 | 4.20 | |
|
MOX430-17HFN8-OPP/MSOPP-17HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.12 | -10° | 5.00 | 4.20 | |
|
MOX430-17HFN8-QRD6GW/MSOPBU-18HRFN8-QRD6GW
Oasis Plus
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
OP-17RE1H-O/OP-17RE1-I
Oasis Plus
|
MIDEA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.12 | -10° | 5.00 | 4.20 | |
|
AOYG18KBTB/ARXG18KHTAP
ARY**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXG18KHTAP
ARXG**K
|
FUJITSU | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
MOX431-18HFN8-QRD6GW/MSGPCU-18HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MOX431-18HFN8-QRD6GW/MSEZCU-18HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EZ-18RD6-O/EZ-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EZ-18RD6H-O/EZ-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EZ-18RD6-O/EZB-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EZ-18RD6H-O/EZB-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
AIRGRN-18HFN8-O/AIRGRN-18HRFN8-I V1
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
LINEPRO-18HFN8-O/LINEPRO-18HRFN8-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MOX2-18HFN8CF/MSEZ-18HFN8CF
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MX4-18RD6/EZ-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MX4-18RD6/EZB-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MX4H-18RD6/EZ-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
MX4H-18RD6/EZB-18RD6-I
Solstice
|
MIDEA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
AOYG18KBTB/AUXG18KRLB
AUY**K
|
FUJITSU | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
M2OF-18HFN8-Q/MSEPBU-09HRFN8-QRD6GW+MSEPBU-09HRFN8-QRD6GW
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
M2OF-18HFN8-Q/MSAGBU-09HRFN8-QRD1GW(GA)+MSAGBU-09HRFN8-QRD1GW(GA)
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
MOX330U-18HFN8-QRD0W(GA)/MTJ-18HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MOX330U-18HFN8-Q(GA)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MO-18N8-Q/MTJU-18NX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MOX330U-18HFN8-Q(H)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
AOYG18KBTB/ARXG18KLLAP
ARY**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
MOX430-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
MOX430-18HFN8-QRD0GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AEP2-18NXD6-O/AEP2-18NXD6-I
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX430-18HFN8(R)/MSEPCU-18HRFN8(R)
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX430-18HFN8/MSEPCU-18HRFN8
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
MOX4-18HFN8AD/MSEP-18HFN8AD
All easy-R32
|
MIDEA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 |