Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(2)
AUX
(3)
BOSCH
(5)
BRYANT
(1)
Buderus
(2)
CARRIER
(5)
CIAT
(3)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(25)
EQUATION
(0)
FUJI ELECTRIC
(3)
FUJITSU
(9)
Fujitsu Atlantic
(5)
GENERAL
(5)
GREE
(1)
GSS
(0)
HAIER
(25)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(2)
IVT
(1)
Inventor
(8)
KAYSUN
(3)
LG
(11)
MIDEA
(68)
MITSUBISHI ELECTRIC
(20)
Mitsubishi Heavy Industries
(3)
NORD
(6)
Nobu
(1)
PANASONIC
(18)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(3)
TOSHIBA
(15)
Viessmann
(1)
Vulcano
(1)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
RAV-GP561ATW-E/RAV-HM561BTP-E
SDI
|
TOSHIBA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.81 | 4.27 | 3.48 | -27° | 5.00 | 3.80 | |
|
UUB1 U20 / UV18F N10
UU
|
LG | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.29 | -10° | 5.00 | 4.20 | |
|
UUB1 U20 / CM18F N10
UU
|
LG | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.30 | -10° | 5.00 | 4.10 | |
|
UUB1 U20 / CM18F N11
UU
|
LG | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.30 | -10° | 5.00 | 4.10 | |
|
AOEG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/ARXH18KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
AOHG18KLTA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLTA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOHG18KLCA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLCA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOEG18KLCA/ASEG18KLCA
ASE**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG053KLCA/ASYG053KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
MUZ-SF50VE/MSZ-SF50VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.41 | -15° | 5.00 | 4.20 | |
|
SUZ-M50VA/MLZ-KP50VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
SUZ-M50VA/MFZ-KT50VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/MFZ-KT50VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.21 | -10° | 5.00 | 4.30 | |
|
MUZ-SF50VEH/MSZ-SF50VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.41 | -20° | 5.00 | 4.20 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
RAV-GM562ATP-E/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.11 | 3.27 | -15° | 5.00 | 2.80 | |
|
AUW52U4RJ8/AKT52UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.50 | -10° | 4.90 | 3.50 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UD3EAW
2017
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
RXM60R / FCAG60B
RXM
|
DAIKIN | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.38 | -15° | 5.70 | 4.71 | |
|
CU-RZ50WKE / CS-RZ50WKEW
2019
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50ZKE / CS-RZ50ZKEW
2023
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-RZ50CKE / CS-RZ50CKEW
2025
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.41 | -15° | 5.00 | 4.00 | |
|
AB50S2SC1FA/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.47 | 3.42 | -10° | 5.00 | 4.00 | |
|
SRC60ZSX-W3/FDTC60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.45 | 4.10 | 3.13 | -20° | 5.60 | 5.10 | |
|
MUZ-BT50VG/MSZ-BT50VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.48 | -15° | 5.00 | 3.80 | |
|
MUZ-BT50VG2/MSZ-BT50VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.48 | -15° | 5.00 | 3.80 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
MOX430-18AFN8-QRD1GW/MSEPCU-18HRFN8-QRD1GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
MOX430-18HFN8-QRD1GW/MSEPCU-18HRFN8-QRD1GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
MOX430-18AFN8-QRD1GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
MOX430-18HFN8-QRD1GW/MSEPCU-18HRFN8-QRD0GW
All easy-R32
|
MIDEA | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 |