Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(1)
AUX
(14)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(2)
DAIKIN
(1)
DE DIETRICH
(1)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(2)
Fujitsu Atlantic
(1)
GENERAL
(1)
GREE
(0)
GSS
(0)
HAIER
(18)
HEC
(1)
HEIWA
(0)
HISENSE
(0)
HITACHI
(1)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(6)
MIDEA
(0)
MITSUBISHI ELECTRIC
(7)
Mitsubishi Heavy Industries
(1)
NORD
(7)
Nobu
(1)
PANASONIC
(2)
PITSOS
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(2)
TOSHIBA
(12)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(1)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-FT50VGHZ2/MSZ-FT50VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.30 | 3.85 | -25° | 5.00 | 5.00 | |
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
RAV-GM562ATP-E/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.11 | 3.27 | -15° | 5.00 | 2.80 | |
|
MUZ-BT50VG/MSZ-BT50VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.48 | -15° | 5.00 | 3.80 | |
|
MUZ-BT50VG2/MSZ-BT50VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.48 | -15° | 5.00 | 3.80 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
ASW-H18E3A4/MAR3DI-C0 / ASW-H18E3A4/MAR3DI-C0
M SERIES
|
AUX | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.20 | -10° | 5.40 | 4.60 | |
|
ASW-H18E3E4/CAR3DI-C0 / ASW-H18E3E4/CAR3DI-C0
C SERIES
|
AUX | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.20 | -10° | 5.40 | 4.60 | |
|
ASW-H18E3B4/MAR3DI-C0 / ASW-H18E3B4/MAR3DI-C0
M SERIES
|
AUX | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.20 | -10° | 5.40 | 4.60 | |
|
ASW-H18E3A4/CAR3DI-C0 / ASW-H18E3A4/CAR3DI-C0
C SERIES
|
AUX | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.20 | -10° | 5.40 | 4.60 | |
|
ASW-H18E3B4/CDR3DI-C0 / ASW-H18E3B4/CDR3DI-C0
C SERIES
|
AUX | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.20 | -10° | 5.40 | 4.60 | |
|
ASW-H18E3E4/MAR3DI-C0 / ASW-H18E3E4/MAR3DI-C0
M SERIES
|
AUX | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.20 | -10° | 5.40 | 4.60 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
MUZ-DW50VF/MSZ-DW50VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF/MSZ-HR50VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF2/MSZ-HR50VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
SRC50ZSP-W1/SRK50ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.37 | -10° | 5.00 | 3.80 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
3N60WEAFRA-W/AS25SAT1-W+AS35SAT1-W
Serene-Multisplit
|
NORD | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 5.20 | 4.60 | |
|
ASW-H18E3G4/JAR3DI-C0 / ASW-H18E3G4/JAR3DI-C0
J SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
ASW-H18E3G4/QCR3DI-C0 / ASW-H18E3G4/QCR3DI-C0
Q SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.10 | -10° | 5.30 | 3.90 | |
|
ASW-H18E3H4/JAR3DI-C0 / ASW-H18E3H4/JAR3DI-C0
J SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
NOBO-18/NOBI-18WFI
Nobu
|
Nobu | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
MOSE 2 50 (7885144) / UMS 2 50 (7910478)
CLIM'UP SMART
|
DE DIETRICH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
UUA1 UL0 / CM18F N10
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
UUA1 UL0 / CM18F N11
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
RAC-CJ50WHAE / RAK-CJ50PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -15° | 4.60 | 4.35 | |
|
RXM50A8 / FDXM50F9
RXM
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.89 | 2.99 | -15° | 5.00 | 4.00 | |
|
RAV-GV561ATP-E/RAV-HM561BTP-E
DIC
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 3.21 | -15° | 5.00 | 2.80 | |
|
RAS-18B2AVG-E2/RAS-B18B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18LAV2G-E/RAS-B18LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
38WHSS050ATA0TEE/40WHSW050DTA0TEE
40WHS
|
CARRIER | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
UUA1 UL0 / CT18F NQ0
UU
|
LG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.60 | -10° | 5.00 | 2.80 | |
|
ASW-H18E2B4/QAR3DI-C0 / ASW-H18E2B4/QAR3DI-C0
Q SERIES
|
AUX | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
RTX52MQC-T1B/FTXM52QC-B
Q SERIES
|
XTRON | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
ASW-H18E2B4/QCR3DI-C0 / ASW-H18E2B4/QCR3DI-C0
Q SERIES
|
AUX | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
RTX52MQH-T1B/FTXM52QH-B
Q SERIES
|
AUX | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
ASW-H18E0D4/ZAR3DI-C0 / ASW-H18E0D4/ZAR3DI-C0
Z SERIES
|
AUX | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
FUTO-18/FUTI-18WFI
Futura AI
|
Inventor | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
ASW-H18E0E4/ZAR3DI-C0 / ASW-H18E0E4/ZAR3DI-C0
Z SERIES
|
AUX | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 |