Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(1)
AUX
(14)
BOSCH
(10)
BRYANT
(0)
Buderus
(5)
CARRIER
(10)
CIAT
(3)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(31)
EQUATION
(1)
FUJI ELECTRIC
(2)
FUJITSU
(9)
Fujitsu Atlantic
(3)
GENERAL
(6)
GREE
(1)
GSS
(0)
HAIER
(44)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(9)
IVT
(0)
Inventor
(2)
KAYSUN
(0)
LG
(0)
MIDEA
(25)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(2)
NORD
(3)
Nobu
(0)
PANASONIC
(11)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(3)
TOSHIBA
(12)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEG18KBCA3/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 | |
|
AOHG18KBTA3/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.89 | -15° | 5.40 | 5.00 | |
|
SCM45ZS-W/SRK20ZSX-W/SRK25ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 4.70 | 5.00 | -15° | 4.50 | 4.10 | |
|
AOYG18KBTA2/ASYG09KGTB/ASYG09KGTB
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
ROG18KBTA2/RSG09KGTB/RSG09KGTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOHG18KBTA2/ASHG09KGTB/ASHG09KGTB
AOH**K Multi
|
GENERAL | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYG09KGTE/ASYG09KGTE
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOEG18KBCA2/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYH09KGTG/ASYH09KGTG
AOY**K Multi
|
FUJITSU | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOHG18KBTA2/ASHH09KGTG/ASHH09KGTG
AOH**K Multi
|
GENERAL | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYG09KGTB/ASYG09KGTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
AOYG18KBTA2/ASYG09KGTE/ASYG09KGTE
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 4.59 | -15° | 5.00 | 4.20 | |
|
2MXM50A9 / FTXA25C / FTXA25C
2MXM
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.53 | 4.61 | 4.08 | -15° | 5.00 | 4.20 | |
|
2MXM50A9 / FTXM25A / FTXM25A
2MXM
|
DAIKIN | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.53 | 4.61 | 4.08 | -15° | 5.00 | 4.20 | |
|
SCM50ZS-W/SRK25ZSX-W/SRK25ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.70 | 5.17 | -10° | 5.00 | 4.80 | |
|
2MXM50A9 / FTXA35C / CTXA15C
2MXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.53 | 4.61 | 4.07 | -15° | 5.00 | 4.00 | |
|
2MXM50A9 / FTXM35A / CTXM15A
2MXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.53 | 4.61 | 4.07 | -15° | 5.00 | 4.00 | |
|
RAS-2M18G3AVG-E/RAS-B16G3KVSG-E+RAS-B16G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.90 | 5.05 | -20° | 5.20 | 3.20 | |
|
38WH2M052C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.90 | 5.05 | -20° | 5.20 | 3.20 | |
|
RAS-2M18G3AVG-E/RAS-B16P2KVSG-E+RAS-B16P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.90 | 5.05 | -20° | 5.20 | 3.20 | |
|
RAM-53NYP3E / RAK-18QXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.61 | 4.61 | 4.20 | -15° | 5.30 | 6.00 | |
|
RAS-2M18G3AVG-E/RAS-B16G3KVSG-E+RAS-B13G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.91 | -20° | 5.20 | 3.20 | |
|
38WH2M052C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.91 | -20° | 5.20 | 3.20 | |
|
RAS-2M18G3AVG-E/RAS-B16P2KVSG-E+RAS-B13P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.91 | -20° | 5.20 | 3.20 | |
|
RAM-G55N2HAE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
RAM-G55N2HBE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
CU-2Z50ABEC/CS-HZ25ZKE/CS-HZ25ZKE
2024
|
PANASONIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.60 | 4.71 | -25° | 5.30 | 5.20 | |
|
RXYM52M(2)-T1A+FTXM26CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.70 | 4.30 | -10° | 5.20 | 4.70 | |
|
RXYM52M(2)-T1A+FTXM26CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.70 | 4.30 | -10° | 5.20 | 4.70 | |
|
CU-2Z50CBE / CS-Z25CKEW / CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 4.63 | -15° | 5.00 | 4.20 | |
|
RAM-G55N3HCE / RAK-XJ18QHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 4.20 | -10° | 5.50 | 5.60 | |
|
AJ050TXJ2KG / AR70F09CAAW / AR70F09CAAW
FJM
|
SAMSUNG | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.54 | 4.64 | 4.38 | -10° | 5.00 | 4.21 | |
|
2MXM50A9 / FTXM25R / FTXM25R
2MXM
|
DAIKIN | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.61 | 4.08 | -10° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25R / ATXM25R
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25A / ATXM25A
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
M2OF-18HFN8-Q/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
2MXM50A9 / FTXM35R / CTXM15R
2MXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.61 | 4.07 | -10° | 5.00 | 4.00 | |
|
RAM-G55N3HAE / RAK-XJ18QHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.76 | 4.60 | 4.20 | -15° | 5.50 | 5.60 | |
|
U-50PZH3E5/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.03 | -20° | 5.00 | 4.50 | |
|
3MXM52A8 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -20° | 5.00 | 4.80 | |
|
RAM-G55N2HCE / RAK-XJ18QHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 5.50 | 5.60 | |
|
3MXM52A9 / FTXM25R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25R / FTXM25R
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25A / FTXM25A
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP25N9 / FTXP25N9
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 |