Filters · 8 active
Manufacturer:
AIRCLASS
BOSCH
COLIBRI
Fujitsu Atlantic
SAMSUNG
Viessmann
Vulcano
AIRWELL
(19)
ATLANTIC
(4)
AUX
(39)
BRYANT
(1)
Buderus
(7)
CARRIER
(32)
CIAT
(6)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
DE DIETRICH
(3)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
GENERAL
(31)
GREE
(30)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(71)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(10)
LG
(79)
MIDEA
(163)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
PITSOS
(1)
RIELLO
(6)
Rotenso
(0)
THERMOR
(12)
TOSHIBA
(68)
WESTPOINT
(6)
XTRON
(1)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AJ080TXJ4KH / AJ020TNAPKH / AJ068TNAPKH
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
AJ080TXJ4KG / AR60F07C1AW / AR70F24C1AW
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.28 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
AJ068TXJ3KG / AR60F07C1AW / AR70F18C1AW
FJM
|
SAMSUNG | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.85 | 3.92 | -10° | 6.50 | 5.09 | |
|
AR24BXHQASIN / AR24BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -10° | 7.00 | 4.70 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
UE-E3CM 82/4 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AR40H24C1AMN/AR40H24C1AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0AMN/AR40F24C0AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0BMN/AR40F24C0BMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AJ068TXJ3KH / AJ025TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.02 | 4.00 | 3.82 | -10° | 6.80 | 5.09 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
UE-EC 70 / UI-ECU M 70
Easy 3 Cool
|
Vulcano | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
CL5000M 79/3 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
UE-E3CM 79/3 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
CL5000M 62/3 E / CL3000iU W 26 E + CL3000iU W 35 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
UE-E3CM 62/2 / UI-L2CU M 26 + UI-L2CU M 35
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
Vitoclima 050-S IWAA050MFA070/Vitoclima 050-S OWAA050MFA070
Wall mounted
|
Viessmann | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
AOYG24KBTB/AUXG24KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.69 | -15° | 6.80 | 6.00 | |
|
AOYG24KATA/AUXG24KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.81 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AOYG24KATA/ARXG24KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG24KATA/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.81 | -15° | 6.80 | 5.40 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24AW31/ASI24AW31
Series 6
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
Vitoclima100-SIC8AA100MFA070/Vitoclima100-SPROOFAA100MFP070
Cassette
|
Viessmann | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOYG22KATA/AUXG22KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
AR50F24C1AHN/AR50F24C1AHX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR50F24C1BHN/AR50F24C1BHX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AJ080HCJ4KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.97 | 4.16 | 4.00 | -10° | 8.00 | 5.65 |