Filters · 8 active
Manufacturer:
AIRCLASS
BOSCH
CARRIER
COLIBRI
Vulcano
WESTPOINT
YORK
AIRWELL
(19)
ATLANTIC
(4)
AUX
(39)
BRYANT
(1)
Buderus
(7)
CIAT
(6)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
DE DIETRICH
(3)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(30)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(71)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(10)
LG
(79)
MIDEA
(163)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
PITSOS
(1)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
XTRON
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
YHKF24XEEBMH-RY / YHKF24YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.90 | 3.40 | -10° | 7.20 | 4.90 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
UE-E3CM 82/4 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
UE-EC 70 / UI-ECU M 70
Easy 3 Cool
|
Vulcano | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
YHKF24YEEBMJO-X/YHKF24XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
YHKF24YEEBMJO-T/YHKF24XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL5000M 79/3 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
UE-E3CM 79/3 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
CL5000M 62/3 E / CL3000iU W 26 E + CL3000iU W 35 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
UE-E3CM 62/2 / UI-L2CU M 26 + UI-L2CU M 35
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
42QCE021D8S* / 38QCE021D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.26 | -10° | 6.12 | 4.75 | |
|
42QHA024D8S*/38QHA024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42QHF024D8S*/38QHF024D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
38WHSS071ATA0TEE/40WHSW071DTA0TEE
40WHS
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
YUKF24BYEEBMO-1/YKKF24BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
42QHG022D8S*/38QHG022D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.74 | -10° | 6.25 | 4.90 | |
|
42QHG024D8S*/38QHG024D8S*
Wall mounted
|
CARRIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
42QTD024D8S*/38QUS024D8S*
Cassette
|
CARRIER | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24AW31/ASI24AW31
Series 6
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
WIMO-24222.MH / WIM-24222.MH
WIM 222
|
WESTPOINT | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
42QCE024D8SP*/38QCE024D8SP
Wall mounted
|
CARRIER | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
42QCE024D8SM*/38QCE024D8SM
Wall mounted
|
CARRIER | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
42QTD024D8S*/38QUS024D8SX*
Cassette
|
CARRIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
38WH5M100C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 4.07 | -20° | 6.00 | 4.19 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42QSS024D8S*/38QUS024D8S*
Ducted
|
CARRIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
YUKF24BYEEBMO-1/YEKF24BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
38WHSH071A1A0TEE/40WHHW071D1A0TEE
40WHH
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -15° | 7.00 | 6.30 | |
|
38WHSH071A1A0TEE/40WHHB071D1A0TEE
40WHH
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.40 | -15° | 7.00 | 6.30 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 4.14 | -20° | 7.10 | 4.93 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW035D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.20 | -20° | 8.10 | 5.49 | |
|
42QZL024D8S*/38QUS024D8SX*
Ceiling suspended
|
CARRIER | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
38WHSM071A1A0TEE/40WHMW071D1A0TEE
40WHM
|
CARRIER | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
38WH4M080C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.19 | 4.30 | 4.63 | -20° | 6.00 | 4.27 | |
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 |