Filters · 9 active
Manufacturer:
AIRCLASS
BOSCH
CIAT
COLIBRI
SAMSUNG
Vulcano
WESTPOINT
YORK
AIRWELL
(19)
ATLANTIC
(4)
AUX
(39)
BRYANT
(1)
Buderus
(7)
CARRIER
(32)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
DE DIETRICH
(3)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(30)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(71)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(10)
LG
(79)
MIDEA
(163)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
PITSOS
(1)
RIELLO
(6)
Rotenso
(0)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
XTRON
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AJ080TXJ4KH / AJ020TNAPKH / AJ068TNAPKH
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
AJ080TXJ4KG / AR60F07C1AW / AR70F24C1AW
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.28 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
AJ068TXJ3KG / AR60F07C1AW / AR70F18C1AW
FJM
|
SAMSUNG | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.85 | 3.92 | -10° | 6.50 | 5.09 | |
|
AR24BXHQASIN / AR24BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -10° | 7.00 | 4.70 | |
|
YHKF24XEEBMH-RY / YHKF24YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.90 | 3.40 | -10° | 7.20 | 4.90 | |
|
CL5000M 82/4 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
UE-E3CM 82/4 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
AR40H24C1AMN/AR40H24C1AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0AMN/AR40F24C0AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0BMN/AR40F24C0BMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AJ068TXJ3KH / AJ025TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.02 | 4.00 | 3.82 | -10° | 6.80 | 5.09 | |
|
CL2000 70 E / CL2000U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
UE-EC 70 / UI-ECU M 70
Easy 3 Cool
|
Vulcano | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
YHKF24YEEBMJO-X/YHKF24XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL2001 70 E / CL2001U W 70 E
Climate 2000
|
BOSCH | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
YHKF24YEEBMJO-T/YHKF24XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
CL5000M 79/3 E / CL3000iU W 26 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
UE-E3CM 79/3 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
CL5000M 62/3 E / CL3000iU W 26 E + CL3000iU W 35 E
Climate 5000 M
|
BOSCH | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
UE-E3CM 62/2 / UI-L2CU M 26 + UI-L2CU M 35
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
42HF24JS8C-1/38HF24JS8C-1
Wall mounted
|
CIAT | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
CL5000L 70 E / CL5000iU 4C 70 E
Climate 5000i L
|
BOSCH | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
YUKF24BYEEBMO-1/YKKF24BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
42HC24JS8C*/38HC24JS8C*
Wall mounted
|
CIAT | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24AW31/ASI24AW31
Series 6
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
WIMO-24222.MH / WIM-24222.MH
WIM 222
|
WESTPOINT | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HY24VDS8C/38HU24VDS8C
Ducted
|
CIAT | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
YUKF24BYEEBMO-1/YEKF24BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
AR50F24C1AHN/AR50F24C1AHX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR50F24C1BHN/AR50F24C1BHX
RAC
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AJ080HCJ4KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.97 | 4.16 | 4.00 | -10° | 8.00 | 5.65 | |
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
AR70F24C1AWN/AR70F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1AWN/AR60F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 |