Filters · 4 active
Manufacturer:
CIAT
PANASONIC
WESTPOINT
AIRCLASS
(1)
AIRWELL
(19)
ATLANTIC
(4)
AUX
(20)
BOSCH
(16)
BRYANT
(1)
Buderus
(7)
CARRIER
(30)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(25)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(57)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(9)
LG
(78)
MIDEA
(162)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
Vulcano
(5)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-3Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
CU-4Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
CU-4Z80TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.85 | -15° | 8.00 | 5.50 | |
|
42HF24JS8C-1/38HF24JS8C-1
Wall mounted
|
CIAT | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
42HC24JS8C*/38HC24JS8C*
Wall mounted
|
CIAT | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.41 | -10° | 7.04 | 5.20 | |
|
CU-FZ60WKE / CS-FZ60WKE
2019
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.15 | -15° | 6.00 | 4.40 | |
|
CU-BZ60XKE / CS-BZ60XKE
2022
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.16 | -15° | 6.00 | 4.40 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
CU-TZ71WKE / CS-TZ71WKEW
2019
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.51 | -15° | 7.10 | 5.50 | |
|
CU-BZ60ZKE / CS-BZ60ZKE
2023
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.16 | -15° | 6.00 | 4.40 | |
|
CU-BZ60CKE / CS-BZ60CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.16 | -15° | 6.00 | 4.40 | |
|
CU-TZ71ZKE / CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
CU-TZ71CKEW / CS-TZ71CKEW
2025
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HY24VDS8C/38HU24VDS8C
Ducted
|
CIAT | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
CU-Z71YKEA / CS-Z71YKEA
2022
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
CU-Z71YKEA-1 / CS-Z71YKEA-1
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
CU-Z60UBEA / CS-Z60UD3EAW
2017
|
PANASONIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
U-71PZ3E5A / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.40 | 4.23 | -15° | 7.10 | 5.20 | |
|
U-71PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.40 | 4.10 | -15° | 6.90 | 5.20 | |
|
CU-Z71XKE / CS-Z71XKEW
2021
|
PANASONIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.69 | -15° | 7.10 | 5.50 | |
|
CU-Z60UBEA / CS-Z60UB4EAW
2017
|
PANASONIC | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 2.92 | -15° | 6.00 | 4.00 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
CU-Z71ZKE / CS-Z71ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 | |
|
CU-Z71CKE / CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -20° | 7.10 | 5.50 | |
|
CU-TZ60WKE / CS-TZ60WKEW
2019
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.68 | -15° | 6.00 | 4.40 | |
|
CU-TZ60ZKE / CS-TZ60ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.72 | -15° | 6.00 | 4.40 | |
|
CU-4Z80CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.33 | -15° | 8.00 | 6.80 | |
|
CU-TZ60CKE / CS-TZ60CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.72 | -15° | 6.00 | 4.40 | |
|
U-71PZ3E5A / S-6071PF3E
2021
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 4.00 | -15° | 6.80 | 4.70 | |
|
CU-Z60CBEA / CS-Z60CD3EAW
2025
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.24 | -15° | 6.00 | 4.60 | |
|
CU-3Z68CBE / CS-Z50CKEW / CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.15 | -15° | 6.80 | 5.20 | |
|
CU-4Z68CBE / CS-Z50CKEW / CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.15 | -15° | 6.80 | 5.20 | |
|
U-60PZ3E5A / S-60PY3E
2022
|
PANASONIC | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.61 | -15° | 6.00 | 4.60 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
42HE24JS8C*/38HE24JS8C*
Wall mounted
|
CIAT | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
U-71PZH4E5/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E8/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
U-60PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.27 | -15° | 6.10 | 4.60 | |
|
CU-3Z75ABEC/CS-Z50CKEW/CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.32 | -25° | 7.50 | 5.60 | |
|
U-71PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
WIMO-24325.MH / WIM-24325.MH
WIM 325
|
WESTPOINT | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
U-60PZ3E5A / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.70 | 4.39 | -15° | 6.10 | 4.60 |