Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(19)
ATLANTIC
(4)
AUX
(20)
BOSCH
(16)
BRYANT
(1)
Buderus
(7)
CARRIER
(30)
CIAT
(6)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(25)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(57)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(9)
LG
(78)
MIDEA
(162)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
Vulcano
(5)
WESTPOINT
(5)
YORK
(6)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX401-24HFN8/LT/MSAGDU2-24HRFNX
Extreme save R32
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC166i.2-7,0 / AC166i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
M3OG-21HFN8-Q/MCA4U-09HRFNX-QRD1W(GA)+MCA4U-12HRFNX-QRD1W(GA)
M3OG-21HFN8-Q
|
MIDEA | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
U6RSL(3)-21/LV6iCI-09WiFiR+LV6iCI-12WiFiR
ODU + Cassette
|
Inventor | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
M3OG-21HFN8-Q(H)/MCA4U-09HRFNX(GA)+MCA4U-12HRFNX(GA)
M3OG-21HFN8-Q
|
MIDEA | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
ZDAA-3060-09M25/CDMD-025N-09M25/CDMD-035N-09M25
ZDAA
|
AIRWELL | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | -10° | 6.10 | 5.10 | |
|
AC70FW0EW/HC70FW00G
Max Comfort
|
HISENSE | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.60 | -10° | 6.50 | 5.30 | |
|
RAV-GM802ATW-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 4.00 | 3.11 | -15° | 6.70 | 5.10 | |
|
MOX401-24HFN8-QRD0GW/MSCB1DU-24HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
CB1-24HFNX-O/CB1-24HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MOX401-24HFN8/MSCB1DU-24HRFN8
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
CB1-24HFNX-O(A)/CB1-24HRFN8-I(A)
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MOM-24NXD0/MCB1-24N8
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MOX401-24HFN8-ME/MSCB1DU-24HRFN8-ME
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
CB1-24HFNX-O-GR/CB1-24HRFN8-I-GR
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
CB1-24HFN8-O/CB1-24HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MOM-24NXD0/CB1-24HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MX4-24RD1-CB/CB1-24HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MX4-24RD1-CB/CB1-24HRFN8-UV
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
MX4H-24RD1-CB/CB1-24HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.59 | -10° | 7.00 | 4.70 | |
|
ARXF60A / ATXF60A
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.03 | 3.90 | -15° | 6.00 | 4.80 | |
|
ARXF60A9 / ATXF60A
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.03 | 3.90 | -15° | 6.00 | 4.80 | |
|
ARXF60A9 / ATXF60F
ARXF
|
DAIKIN | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.03 | 3.90 | -15° | 6.00 | 4.80 | |
|
MXZ-6F120VF2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.99 | 3.28 | -15° | 8.30 | 9.00 | |
|
MXZ-6F120VF3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.99 | 3.28 | -15° | 8.30 | 9.00 | |
|
AL-H24/4DR3HB3(U) / AUCA-H24/4DR3HB2
Q-Cassette
|
AUX | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
RXYL71M-T1B/FDCA71Q-B
Q-Cassette
|
AUX | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 6.40 | |
|
RXF60D / FTXF60D
RXF
|
DAIKIN | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -15° | 6.00 | 4.80 | |
|
RAV-GM802ATW-E/RAV-HM801SDTY-E
DI
|
TOSHIBA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 4.00 | 3.44 | -15° | 6.70 | 5.10 | |
|
UUC1 U40 / CL24F N30
U4
|
LG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 3.90 | 3.52 | -10° | 6.80 | 5.40 | |
|
MOX430-24HFN8-QRD1GW/MSGPDU-24HRFN8-QRD1GW
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
MX4-24RD1-EF/EF-24RD1
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD1-EF/EF-24RD1
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
NRO-24/NRI-24WFI
Nura
|
Inventor | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
DURA-24RD1-OUT/DURA-24RD1-IN
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
LINE-24RD1-OUT/LINE-24RD1-IN
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
MGPXV-24RD0-O/MGPXV-24RD0-I
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
MGPXVH-24RD0-O/MGPXV-24RD0-I
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
PRO-24RD1-OUT/PRO-24RD1-IN
Solunar
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.41 | -10° | 7.00 | 4.80 | |
|
MU4R27 U42 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.70 | 3.80 | 3.60 | -10° | 6.80 | 6.70 | |
|
M4OA-27HFN8-Q(HRU)/MSAFAU-09HRFN8-QRD1GW+MSAFCU-18HRFNX-QRD0GW
M4OA-27HFN8-Q(HRU)
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.48 | -10° | 7.90 | 6.20 | |
|
GWHD(24)NK6QO GWH12AGCXD-K6DNA1D/I*2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 7.10 | 6.10 | |
|
UUB1 U20 / US30F NR0
UU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.60 | -10° | 7.50 | 4.30 | |
|
ARXC60D / ATXC60D
ARXC
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.38 | 4.19 | 3.71 | -14° | 6.21 | 4.10 | |
|
U7RS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MU5R30 U42 / MJ12PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 3.80 | 3.40 | -10° | 7.30 | 6.90 | |
|
AC71S2SG1FA/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
AD71S2SM9FA(H)/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.06 | 4.00 | 3.34 | -10° | 6.80 | 5.00 | |
|
AS71S2SF1FA-MB3/1U71S2SR2FA
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 |