Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(1)
AUX
(10)
BOSCH
(3)
BRYANT
(0)
Buderus
(1)
CARRIER
(4)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(10)
FUJITSU
(24)
Fujitsu Atlantic
(10)
GENERAL
(14)
GREE
(3)
GSS
(0)
HAIER
(22)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(9)
IVT
(0)
Inventor
(2)
KAYSUN
(2)
LG
(3)
MIDEA
(22)
MITSUBISHI ELECTRIC
(22)
Mitsubishi Heavy Industries
(15)
NORD
(0)
Nobu
(0)
PANASONIC
(1)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(3)
TOSHIBA
(15)
Viessmann
(1)
Vulcano
(1)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC71VNX-W/FDU71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.47 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDUM71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.45 | 4.49 | -20° | 7.10 | 6.00 | |
|
AOEG30KBTA4/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOHG30KBTA4/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.55 | -15° | 8.00 | 6.50 | |
|
AOEG24KBCA3/ASEH07KMCG/ASEH09KMCG/ASEH09KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTA3/ASHH07KMCG/ASHH09KMCG/ASHH09KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 6.80 | 6.00 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B50G3KVSG-ND
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 3.74 | -25° | 6.00 | 6.50 | |
|
MOX430UL-24HFN8-QRD0W/MFYC400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.30 | 3.70 | -10° | 7.10 | 6.10 | |
|
RAV-GM902ATW-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 4.12 | -15° | 8.00 | 6.30 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RAV-GM902ATW-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.60 | 4.00 | -15° | 8.00 | 6.30 | |
|
RAV-GM902ATW-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.75 | 4.30 | 4.00 | -15° | 8.00 | 6.30 | |
|
RAV-GM901ATP-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -15° | 8.00 | 6.30 | |
|
MUZ-LN60VG2/MSZ-LN60VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
MUZ-LN60VG3/MSZ-LN60VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
SRC71ZR-W/SRK71ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -15° | 7.10 | 6.60 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDE40VH/FDE40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.48 | 4.49 | 3.81 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDTC40VH/FDTC40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.37 | -20° | 7.10 | 6.00 | |
|
MUZ-AP71VG2/MSZ-AP71VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 3.82 | -15° | 7.10 | 6.70 | |
|
MUZ-AP71VG2/MSZ-AP71VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 3.82 | -15° | 7.10 | 6.70 | |
|
MUZ-AP71VG3/MSZ-AP71VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 3.82 | -15° | 7.10 | 6.70 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B35S4KVPG-ND
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 3.74 | -25° | 6.00 | 6.50 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
SRC80ZR-W/SRK80ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.96 | -15° | 8.00 | 7.10 | |
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOEH24KMTG/ASEH24KMTGL
ASE**K
|
FUJITSU | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
SRC71ZR-W/SRK71ZR-WF
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -10° | 7.10 | 6.60 | |
|
RAS-3HVRC3 / RCI-3.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.20 | 4.35 | -25° | 7.10 | 6.00 | |
|
RCI-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.73 | 4.33 | 4.07 | -15° | 7.00 | 6.00 | |
|
AOEG24KBTB/ARXH24KMTAP
ARXH**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
M4OA-27HFN8-Q(HRU)/MTJ-09HWFNX-QRD1W(GA)+MTJ-18HWFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.90 | 6.30 | |
|
FDC71VNX-W/FDUM40VH/FDUM40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.15 | 4.44 | -20° | 7.10 | 6.00 | |
|
RAV-GM901ATP-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEG24KMTA/ASEG24KMTE
ASE**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEH30KMTB/ASEH30KMTB
ASE**K
|
FUJITSU | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOHH30KMTB/ASHH30KMTB
ASY**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOYH30KMTB/ASYH30KMTB
ASY**K
|
FUJITSU | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
ROH30KMTB/RSH30KMTB
RS**K
|
FUJI ELECTRIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOYH30KMTB/ASYH30KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
SRC80ZR-W/SRK80ZR-WF
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.96 | -10° | 8.00 | 7.10 |