Filters · 3 active
Manufacturer:
HITACHI
KAYSUN
AIRCLASS
(1)
AIRWELL
(19)
ATLANTIC
(4)
AUX
(20)
BOSCH
(16)
BRYANT
(1)
Buderus
(7)
CARRIER
(30)
CIAT
(6)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(25)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(57)
IVT
(1)
Inventor
(31)
LG
(78)
MIDEA
(162)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
Vulcano
(5)
WESTPOINT
(5)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
RAM-G70N4HAE / RAK-XJ35RHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.62 | 4.20 | -15° | 7.00 | 5.90 | |
|
RAM-G68N3HAE / RAK-XJ18QHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.25 | 4.60 | 4.00 | -15° | 6.80 | 5.90 | |
|
RAM-G70N4HCE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
RAM-G68N3HCE / RAK-XJ18QHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.00 | -10° | 6.80 | 5.90 | |
|
KUE-71 DVR14/KPD-71 DR15
Duct R32
|
KAYSUN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
RAM-Y70N4HAE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
RAC-VJ60WHAE / RAK-V60RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.80 | -15° | 6.00 | 4.80 | |
|
RAS-3HVRC3 / RCI-3.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.20 | 4.35 | -25° | 7.10 | 6.00 | |
|
RCI-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.73 | 4.33 | 4.07 | -15° | 7.00 | 6.00 | |
|
RAC-VJ70WHAE / RAK-VJ70RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 7.00 | 5.40 | |
|
RAC-60NPE / RAK-60RPE
RAC-NPE(D)
|
HITACHI | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.61 | 3.80 | -15° | 6.00 | 4.70 | |
|
RAS-3HVRC3 / RPC-3.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.09 | 3.73 | -25° | 7.10 | 6.00 | |
|
RAC-60NPE / RAI-60RPE
RAC-NPE(D)
|
HITACHI | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.77 | 4.27 | 3.80 | -15° | 6.00 | 4.70 | |
|
KUE-71 DVR14/KPC-71 DR14
Ceiling&Floor R32
|
KAYSUN | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
KAE-P 71 DR9/KAY-P 71 DR12
SUITE Prodigy PRO
|
KAYSUN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
RAS-3HVRC3 / RPI-3.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.92 | 3.84 | -25° | 7.10 | 6.00 | |
|
RAC-70NPD / RAD-70PPD
RAC-NPE(D)
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.09 | 3.64 | -15° | 7.00 | 5.20 | |
|
RAC-60NPE / RAD-60RPE
RAC-NPE(D)
|
HITACHI | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.01 | 3.80 | -15° | 6.00 | 4.60 | |
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
RPIL-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.05 | 3.74 | -15° | 6.90 | 6.00 | |
|
RAC-VJ60NHAE / RAD-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.02 | 3.80 | -10° | 6.00 | 4.60 | |
|
RAC-VJ60NHAE / RAI-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.21 | 3.75 | -10° | 6.00 | 4.70 | |
|
RAC-DJ60WHAE / RAK-DJ60RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.50 | -15° | 6.00 | 4.80 | |
|
KUE-71 DVR13/KPD-71 DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
KUE-71 DVR13/KPD-71V DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
RAC-VJ70NHAE / RAD-VJ70RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.02 | 3.64 | -10° | 7.00 | 5.30 | |
|
RAS-3HVRC3 / RPK-3.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.11 | 3.90 | 3.19 | -25° | 7.10 | 5.60 | |
|
KUE-71 DVR14/KCIS-71 DR14
Cassette R32
|
KAYSUN | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
RAC-DJ70WHAE / RAK-DJ70RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.10 | -15° | 7.10 | 5.40 | |
|
KUE-71 DVR13/KPC-71 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
KUE-71 DVR13/KCIS-71 DR14
ZEN Cassette
|
KAYSUN | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
KAE-C 71 DR11/KAY-CF 71 DR12
SUITE Casual
|
KAYSUN | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 |