Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(16)
ATLANTIC
(4)
AUX
(20)
BOSCH
(13)
BRYANT
(1)
Buderus
(5)
CARRIER
(18)
CIAT
(5)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(81)
EQUATION
(1)
FUJI ELECTRIC
(21)
FUJITSU
(50)
Fujitsu Atlantic
(23)
GENERAL
(23)
GREE
(13)
GSS
(1)
HAIER
(98)
HEC
(0)
HEIWA
(1)
HISENSE
(50)
HITACHI
(17)
IVT
(0)
Inventor
(27)
KAYSUN
(8)
LG
(66)
MIDEA
(136)
MITSUBISHI ELECTRIC
(66)
Mitsubishi Heavy Industries
(10)
NORD
(8)
Nobu
(2)
PANASONIC
(31)
RIELLO
(5)
Rotenso
(0)
SAMSUNG
(30)
THERMOR
(12)
TOSHIBA
(40)
Viessmann
(4)
Vulcano
(5)
WESTPOINT
(0)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD71ZD1/A-S/GUD71W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | -10° | 7.10 | 4.70 | ||
|
RAV-GP801ATW-E/RAV-HM801FT-E
SDI
|
TOSHIBA | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.43 | 3.38 | -27° | 7.10 | 5.10 | |
|
MOX430UL-24HFN8-QRD0W/MFHA-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.75 | -10° | 7.10 | 5.40 | |
|
RAV-GM802ATW-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.48 | 3.87 | -15° | 6.90 | 5.10 | |
|
MOX430UL-24HFN8-QRD0W/MFYC400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.30 | 3.70 | -10° | 7.10 | 6.10 | |
|
RAV-GM902ATW-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 4.12 | -15° | 8.00 | 6.30 | |
|
RAM-70NYP4E / RAK-35RXE / RAK-35RXE
RAM-NYPE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.42 | 4.61 | 4.20 | -15° | 7.00 | 6.00 | |
|
UUC1 U40 / UV30FH N20
U4
|
LG | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -10° | 8.00 | 5.40 | |
|
RAM-G70N4HAE / RAK-XJ35RHAE / RAK-XJ35RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.62 | 4.20 | -15° | 7.00 | 5.90 | |
|
RAV-GM902ATW-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.60 | 4.00 | -15° | 8.00 | 6.30 | |
|
RAV-GM902ATW-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.75 | 4.30 | 4.00 | -15° | 8.00 | 6.30 | |
|
RAV-GM901ATP-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -15° | 8.00 | 6.30 | |
|
U-71PZ3E5A / S-6071PU3E
2021
|
PANASONIC | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 4.23 | -15° | 7.10 | 5.20 | |
|
RAV-GM802ATW-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.30 | 3.77 | -15° | 6.70 | 5.10 | |
|
MUZ-LN60VG2/MSZ-LN60VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
MUZ-LN60VG3/MSZ-LN60VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
EMPVO-24/EMPVI-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
EMPVO(W)-24/EMPVI(W)-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
ND71MFAHRA/1N71WEAFRA
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
ND71MFAHRA/1N71WEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
EQO-24/EQI-24WFI
Econ IQ
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
INVBO-24/INVBI-24WFI
Intellia
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
MOX431-24HFN8-QRD6GW/MSGPDU-24HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
RAM-G68N3HAE / RAK-XJ18QHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.25 | 4.60 | 4.00 | -15° | 6.80 | 5.90 | |
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
RAS-22P2AVSG-E/RAS-B22P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
RAS-22P2AVSG-E/RAS-B22P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
U-71PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
MOX430U-24HFN8-QRD1W(GA)/MTJ-24HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W/MTJ-24HWFNX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(GA)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MO-24N8-Q-1/MTJU-24NX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
KUE-71 DVR14/KPD-71 DR15
Duct R32
|
KAYSUN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W(GA)-GR/MTJ-24HWFNX-QRD1W(GA)-GR
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
DDMD-070N-09M25/YDAX-070H-09M25**
DDMD
|
AIRWELL | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(H)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
U-71PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
RAS-22J2AVSG-E1/RAS-B22G3KVSG-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
RAS-22J2AVSG-E1/RAS-B22G3KVSGB-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHW060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHB060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOEH24KMTG/ASEH24KMTGL
ASE**K
|
FUJITSU | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 |