Filters · 2 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(16)
ATLANTIC
(4)
AUX
(20)
BOSCH
(14)
BRYANT
(1)
Buderus
(6)
CARRIER
(18)
CIAT
(6)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(110)
EQUATION
(0)
FUJI ELECTRIC
(22)
FUJITSU
(55)
Fujitsu Atlantic
(26)
GENERAL
(25)
GREE
(17)
GSS
(1)
HAIER
(98)
HEC
(0)
HEIWA
(1)
HISENSE
(37)
HITACHI
(13)
IVT
(0)
Inventor
(26)
KAYSUN
(9)
LG
(31)
MIDEA
(131)
MITSUBISHI ELECTRIC
(99)
Mitsubishi Heavy Industries
(9)
NORD
(8)
Nobu
(2)
PANASONIC
(23)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(17)
THERMOR
(12)
TOSHIBA
(26)
Viessmann
(4)
Vulcano
(5)
WESTPOINT
(4)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG22KBTB/ARXG22KHTAP
ARY**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RDG22KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KHTAP
ARXG**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXH22KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
ND71MFAHRA/1N71WEAFRA
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
ND71MFAHRA/1N71WEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
PUZ-ZM60VHA2/PEAD-M60JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/PEAD-M60JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PEAD-M60JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/PEAD-M60JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.40 | -20° | 6.10 | 4.40 | |
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
PUZ-ZM71VHA2/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
MOX430U-24HFN8-QRD1W(GA)/MTJ-24HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W/MTJ-24HWFNX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(GA)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MO-24N8-Q-1/MTJU-24NX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
KUE-71 DVR14/KPD-71 DR15
Duct R32
|
KAYSUN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W(GA)-GR/MTJ-24HWFNX-QRD1W(GA)-GR
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
DDMD-070N-09M25/YDAX-070H-09M25**
DDMD
|
AIRWELL | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(H)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
RZAG71NV1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RAS-3HVRC3 / RCI-3.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.20 | 4.35 | -25° | 7.10 | 6.00 | |
|
RZAG71NV1 / FNA35A9 / FNA35A9
RZAG
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.14 | 4.14 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FNA35A9 / FNA35A9
RZAG
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.14 | 4.14 | -10° | 6.80 | 4.70 | |
|
RZAG71NV1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
AOEG24KBTB/ARXH24KMTAP
ARXH**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
M4OA-27HFN8-Q(HRU)/MTJ-09HWFNX-QRD1W(GA)+MTJ-18HWFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.90 | 6.30 | |
|
FDC71VNX-W/FDUM40VH/FDUM40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.15 | 4.44 | -20° | 7.10 | 6.00 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEG24KMTA/ASEG24KMTE
ASE**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 |