Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(19)
ATLANTIC
(4)
AUX
(20)
BOSCH
(16)
BRYANT
(1)
Buderus
(7)
CARRIER
(30)
CIAT
(6)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(25)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(57)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(9)
LG
(78)
MIDEA
(162)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
Vulcano
(5)
WESTPOINT
(5)
YORK
(6)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUC1 U40 / UM30FH N20
U4
|
LG | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.97 | -10° | 7.90 | 5.40 | |
|
RAV-GM802ATW-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.30 | 3.77 | -15° | 6.70 | 5.10 | |
|
MUZ-LN60VG2/MSZ-LN60VG2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
MUZ-LN60VG3/MSZ-LN60VG3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.76 | -15° | 6.10 | 6.00 | |
|
RZAG71NV1 / FCAG35B / FCAG35B
RZAG
|
DAIKIN | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.41 | 4.41 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FCAG35B / FCAG35B
RZAG
|
DAIKIN | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.41 | 4.41 | -10° | 6.80 | 4.70 | |
|
AOYG22KBTB/AUXG22KRLB
AUY**K
|
FUJITSU | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/AUXG22KRLB
AUH**K
|
GENERAL | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RCG22KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/AUXG22KRLB
AUXG**K
|
FUJITSU | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/AUXG22KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -15° | 6.00 | 4.80 | |
|
PUZ-M71VHA/PLA-M71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 3.61 | -10° | 7.10 | 4.70 | |
|
M3OC-27HFN8-Q/MSOPBU-09HRFN8-QRE1GWV+MSOPBU-18HRFN8-QRD6GW
M3OC-27HFN8-Q
|
MIDEA | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AC-7,9 MS E+ / AC186i.3-5,3 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
EMPVO-24/EMPVI-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
EMPVO(W)-24/EMPVI(W)-24WFI
Emperor
|
Inventor | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.10 | 5.60 | |
|
AS71SEPHRA-MW/1U71WEPFRA-S
S-MATT
|
HAIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEPHRA-MB/1U71WEPFRA-S
S-MATT
|
HAIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEPHRA-MWV/1U71WEPFRA-SH
S-MATT
|
HAIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEPHRA-MW/1U71WEPFRA-SH
S-MATT
|
HAIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEPHRA-MB/1U71WEPFRA-SH
S-MATT
|
HAIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71PEPHRA-TR/1U71WEPFRA-TR
Wall mounted - Pearl Premium
|
HAIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
GWH24AVEXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 7.10 | 5.60 | |
|
GWH24AWEXF-K6DNA4A
MONOSPLITS
|
GREE | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 7.10 | 5.60 | |
|
AS71QUA1-H/1U71QUA1
NORD - P Premium
|
NORD | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
CU-3Z75ABEC/CS-HZ35ZKE/CS-HZ35ZKE
2024
|
PANASONIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.34 | -25° | 7.00 | 5.70 | |
|
AOYG22KBTB/ARXG22KHTAP
ARY**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KHTAP
ARH**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RDG22KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KHTAP
ARXG**K
|
FUJITSU | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXH22KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 6.00 | 4.80 | |
|
RZAG71NV1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FHA71A9
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.32 | -10° | 6.80 | 4.70 | ||
|
ND71MFAHRA/1N71WEAFRA
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
ND71MFAHRA/1N71WEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
SRC71ZR-W/SRK71ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.50 | 4.10 | -15° | 7.10 | 6.60 | |
|
EQO-24/EQI-24WFI
Econ IQ
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
INVBO-24/INVBI-24WFI
Intellia
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
MOX431-24HFN8-QRD6GW/MSGPDU-24HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 7.00 | 5.10 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
RAM-G68N3HAE / RAK-XJ18QHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.25 | 4.60 | 4.00 | -15° | 6.80 | 5.90 | |
|
RAM-G70N4HCE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
RAM-G68N3HCE / RAK-XJ18QHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.00 | -10° | 6.80 | 5.90 | |
|
MOD30-24AFN8-QRD1GW/MSEPDU-24HRFN8-QRD1GW
All easy-R32
|
MIDEA | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 |