Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(19)
ATLANTIC
(4)
AUX
(20)
BOSCH
(16)
BRYANT
(1)
Buderus
(7)
CARRIER
(30)
CIAT
(6)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(1)
DAIKIN
(141)
EQUATION
(1)
FUJI ELECTRIC
(25)
FUJITSU
(64)
Fujitsu Atlantic
(29)
GENERAL
(31)
GREE
(25)
GSS
(1)
HAIER
(117)
HEC
(0)
HEIWA
(2)
HISENSE
(57)
HITACHI
(26)
IVT
(1)
Inventor
(31)
KAYSUN
(9)
LG
(78)
MIDEA
(162)
MITSUBISHI ELECTRIC
(134)
Mitsubishi Heavy Industries
(33)
NORD
(11)
Nobu
(2)
PANASONIC
(53)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(12)
TOSHIBA
(68)
Viessmann
(4)
Vulcano
(5)
WESTPOINT
(5)
YORK
(6)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX430U-24HFN8-QRD1W/MTJ-24HWFNX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(GA)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MO-24N8-Q-1/MTJU-24NX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
KUE-71 DVR14/KPD-71 DR15
Duct R32
|
KAYSUN | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W(GA)-GR/MTJ-24HWFNX-QRD1W(GA)-GR
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
DDMD-070N-09M25/YDAX-070H-09M25**
DDMD
|
AIRWELL | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
42QSV024D8S*/38QUS024D8SX*
Ducted
|
CARRIER | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(H)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B35S4KVPG-ND
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 3.74 | -25° | 6.00 | 6.50 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
RZASG71MV1 / FDXM35F9 / FDXM35F9
RZASG
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.22 | 4.22 | -10° | 6.80 | 4.50 | |
|
RZASG71MV1 / FNA35A9 / FNA35A9
RZASG
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.22 | 4.22 | -10° | 6.80 | 4.50 | |
|
U-71PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
RAS-22J2AVSG-E1/RAS-B22G3KVSG-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
RAS-22J2AVSG-E1/RAS-B22G3KVSGB-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHW060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
38WHSH060A1A0TEE/40WHHB060D1A0TEE
40WHH
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.72 | -15° | 6.10 | 4.70 | |
|
RAS-4M27G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
38WH4M080C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RAS-4M27G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.55 | 4.40 | 4.70 | -20° | 7.10 | 5.02 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
SRC80ZR-W/SRK80ZR-W
ZR-W
|
Mitsubishi Heavy Industries | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.96 | -15° | 8.00 | 7.10 | |
|
AOHH24KMTG/ASHH24KMTGL
ASH**K
|
GENERAL | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
AOEH24KMTG/ASEH24KMTGL
ASE**K
|
FUJITSU | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.02 | -15° | 7.10 | 7.10 | |
|
RAC-70NPD / RAK-70PPD
RAC-NPE(D)
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 4.41 | 3.81 | -15° | 7.00 | 6.40 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
RZAG71NV1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FBA71A9
RZAG
|
DAIKIN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RAM-Y70N4HAE / RAK-XJ35RHBE / RAK-XJ35RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 7.00 | 5.90 | |
|
RAC-VJ60WHAE / RAK-V60RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.80 | -15° | 6.00 | 4.80 | |
|
SRC63ZTL-W/SRK63ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.53 | -10° | 6.30 | 5.30 | |
|
MOX430-24HFN8-QRD6GW/MSGPDU-24HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MOX430-24HFN8-QRD6GW/MSEZDU-24HRFN8-QRD6GW
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6-O/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6H-O/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6-O/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
EZ-24RD6H-O/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
HDMC-070N-09M25/YDA*-070*-09M25
Harmonia
|
AIRWELL | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4-24RD6/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4-24RD6/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD6/EZ-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
MX4H-24RD6/EZB-24RD6-I
Solstice
|
MIDEA | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
42QCE024D8SH/38QCE024D8SH
Wall mounted
|
CARRIER | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.60 | 3.71 | -10° | 7.00 | 4.80 | |
|
UUC1 U40 / CT24F NB0
U4
|
LG | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.30 | 3.83 | -10° | 6.80 | 5.60 | |
|
UUC1 U40TK / ZTNW24GBLA1
U4
|
LG | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.30 | 3.83 | -10° | 6.80 | 5.60 | |
|
AS70KW00W/HA70KW00G
Uni HA
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.72 | -10° | 7.00 | 5.00 | |
|
AS70KW0EW/HA70KW00G
Uni HA
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 3.72 | -10° | 7.00 | 5.00 |