Filters · 4 active
Manufacturer:
Inventor
SAMSUNG
TOSHIBA
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(4)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(20)
CIAT
(9)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(120)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(122)
Fujitsu Atlantic
(59)
GENERAL
(56)
GREE
(4)
GSS
(0)
HAIER
(97)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(42)
IVT
(0)
KAYSUN
(24)
LG
(77)
MIDEA
(125)
MITSUBISHI ELECTRIC
(138)
Mitsubishi Heavy Industries
(190)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(7)
THERMOR
(0)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.70 | 2.83 | -10° | 12.10 | 8.70 | |
|
U6RSL(5)-42
ODU + Cassette
|
Inventor | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.20 | -10° | 12.30 | 9.00 | |
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 2.80 | -10° | 12.10 | 8.60 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.83 | 3.03 | -10° | 20.00 | 11.40 | |
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.65 | 2.71 | -10° | 20.00 | 11.40 | |
|
U7iRT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.80 | 3.32 | -10° | 20.00 | 11.40 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
U7RS-42/V7CI-42WiFiR
Cassette R32
|
Inventor | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.32 | 3.86 | 3.24 | -10° | 20.00 | 11.40 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
U7RT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
U7RS-36/V7CI-36WiFiR
Cassette R32
|
Inventor | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
U7iRT-50/V7iDI-50WiFiR
Ducted R32
|
Inventor | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
U7RS-42/V7DI-42WiFiR
Ducted R32
|
Inventor | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
U7RS-42/V7iDI-42WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
RAV-GP1101AT8-E/RAV-HM1101KRTP-E
SDI 3ph
|
TOSHIBA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.22 | 3.45 | -20° | 10.00 | 10.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.19 | 4.06 | -20° | 10.00 | 10.80 | |
|
RAV-GP1401AT8-E1/RAV-HM1401FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.02 | 3.00 | -20° | 12.50 | 11.80 | |
|
RAV-GP1601AT8-E/RAV-HM1601UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.38 | 3.74 | -20° | 14.00 | 9.50 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
RAV-GP1401AT8-E1/RAV-HM1401CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.21 | 4.02 | -20° | 12.50 | 11.80 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
RAV-GP1101AT8-E/RAV-HM1101FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.14 | 4.02 | 4.04 | -20° | 10.00 | 10.80 | |
|
RAV-GP1401AT8-E1/RAV-HM1401UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.37 | 4.11 | -20° | 12.50 | 9.50 | |
|
RAV-GP1101AT8-E/RAV-HM1101UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.32 | 4.38 | 4.65 | -20° | 10.00 | 9.50 | |
|
AC120BXAPNG / AC120BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.77 | -25° | 12.10 | 9.20 | |
|
RAV-GP1101AT8-E/RAV-HM1101CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.23 | 4.46 | -20° | 10.00 | 11.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
AC140BXAPNG / AC140BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 3.97 | -25° | 13.40 | 9.50 | |
|
AC140BXAPNG / AC140BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.63 | -25° | 13.40 | 9.50 | |
|
AC120BXAPNG / AC120BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 4.13 | -25° | 12.10 | 9.50 | |
|
RAV-GP1401AT-E1/RAV-HM1401CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.99 | 4.73 | 3.90 | -27° | 12.50 | 9.60 | |
|
RAV-GP1101AT-E/RAV-HM1101KRTP-E
SDI
|
TOSHIBA | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.42 | 3.58 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101BTP-E
SDI
|
TOSHIBA | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.19 | 4.30 | 4.10 | -27° | 10.00 | 9.20 |