Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(43)
EQUATION
(0)
FUJI ELECTRIC
(10)
FUJITSU
(25)
Fujitsu Atlantic
(12)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(4)
HITACHI
(4)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(12)
MIDEA
(0)
MITSUBISHI ELECTRIC
(2)
Mitsubishi Heavy Industries
(54)
NORD
(0)
Nobu
(0)
PANASONIC
(13)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(13)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXG45KHTAP
ARX**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KBTB/RDG45KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ARXG45KHTAP
ARXG**K
|
GENERAL | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ARXG45KHTAP
ARXG**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ARXG45KHTAP
ARX**K
|
FUJITSU | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
MXZ-6F120VF2/MSZ-AP60VG/MSZ-AP60VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.80 | 4.24 | -15° | 9.60 | 9.70 | |
|
MXZ-6F120VF3/MSZ-AP60VGK(P)2/MSZ-AP60VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.80 | 4.24 | -15° | 9.60 | 9.70 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KATA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
FDC125VNX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.09 | 4.08 | 12.50 | 11.40 | ||
|
CU-5Z90CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 4.43 | -15° | 9.00 | 8.50 | |
|
FDC100VNX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
UUD1 U30 / UV36F N20
UU
|
LG | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 4.15 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UV36F N20
UU
|
LG | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 4.15 | -10° | 9.50 | 9.50 | |
|
FDC100VNX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VSX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VNX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.18 | 4.18 | -20° | 10.00 | 11.20 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
AOYG36KBTB/AUXG36KRLB
AUY**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/AUXG36KRLB
AUH**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
ROG36KBTB/RCG36KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOEG36KRTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOEG36KBTB/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KBTB/AUXG36KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG45KBTB/AUXG45KRLB
AUXG**K
|
FUJITSU | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOYG45KRTA/AUXG45KRLB
AUXG**K
|
FUJITSU | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOHG45KBTB/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
ROG45KBTB/RCG45KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
ROG45KRTA/RCG45KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOHG45KRTA/AUXG45KRLB
AUXG**K
|
GENERAL | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOEG45KBTB/AUXG45KRLB
AUX**K
|