Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(1)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(6)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(15)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(8)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VNX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
FDC100VSX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
AOYG36LATT/AUYG36LRLA
AUY**L
|
FUJITSU | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.38 | -15° | 10.00 | 10.00 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 12.40 | 4.14 | 4.14 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 12.40 | 4.14 | 4.14 | 13.40 | 9.52 | ||
|
UUD1 U30 / UT36F NA0
UU
|
LG | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 4.45 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UT36F NA0
UU
|
LG | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 4.45 | -10° | 9.50 | 9.50 | |
|
FDC100VNX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
AUC125UR4RKC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.50 | 3.80 | -10° | 12.10 | 9.00 | |
|
AUC125UR4RKC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.50 | 3.80 | -10° | 12.10 | 9.00 | |
|
UUD1 U30 / UM36FH N30
UU
|
LG | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.20 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36FH N30
UU
|
LG | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.20 | -10° | 9.50 | 9.50 | |
|
RAV-GP1101AT8-E/RAV-HM1101FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.14 | 4.02 | 4.04 | -20° | 10.00 | 10.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.32 | 4.38 | 4.65 | -20° | 10.00 | 9.50 | |
|
UUD1 U30 / UT36FH NA0
UU
|
LG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.50 | 4.50 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UT36FH NA0
UU
|
LG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.50 | 4.50 | -10° | 9.50 | 9.50 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.19 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.19 | 12.10 | 9.52 | |||
|
FDC100VNX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.23 | 12.10 | 9.52 | |||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.00 | 4.23 | 12.10 | 9.52 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.40 | 4.29 | 4.29 | 13.40 | 9.52 | ||
|
RZAG100NV1 / FCAHG100H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.75 | 5.01 | -10° | 9.50 | 9.52 | |
|
RZAG100NY1 / FCAHG100H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.75 | 5.01 | -10° | 9.50 | 9.52 | |
|
FDC100VNX-W/FDT100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.44 | 4.52 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDT100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.44 | 4.52 | -20° | 10.00 | 11.20 | |
|
AC140BXAPNG / AC140BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 3.97 | -25° | 13.40 | 9.50 | |
|
FDC125VNX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.94 | 3.10 | 12.50 | 11.40 | ||
|
AC120BXAPNG / AC120BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 4.13 | -25° | 12.10 | 9.50 | |
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
RAV-GP1101AT-E/RAV-HM1101BTP-E
SDI
|
TOSHIBA | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.19 | 4.30 | 4.10 | -27° | 10.00 | 9.20 | |
|
RZAG125NV1
RZAG
|
DAIKIN | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 12.80 | 5.05 | 5.05 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 12.80 | 5.05 | 5.05 | 12.10 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 13.20 | 5.29 | 5.29 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 13.20 | 5.29 | 5.29 | 12.10 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.85 | 5.85 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 11.20 | 5.85 | 5.85 | 12.10 | 9.52 | ||
|
RAV-GP1101AT-E/RAV-HM1101CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.58 | 4.75 | 4.71 | -27° | 10.00 | 9.20 | |
|
AC100BXAPKG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
AC100BXAPNG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
RAV-GP1101AT-E/RAV-HM1101FT-E
SDI
|
TOSHIBA | Floor standing | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.40 | 4.06 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101UTP-E
SDI
|
TOSHIBA | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.76 | 4.79 | -27° | 10.00 | 9.20 |