Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(4)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(20)
CIAT
(9)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(120)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(122)
Fujitsu Atlantic
(59)
GENERAL
(56)
GREE
(4)
GSS
(0)
HAIER
(97)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(42)
IVT
(0)
Inventor
(25)
KAYSUN
(24)
LG
(77)
MIDEA
(125)
MITSUBISHI ELECTRIC
(138)
Mitsubishi Heavy Industries
(190)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(7)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-4HNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.51 | 4.17 | 3.53 | -20° | 10.00 | 8.70 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
RAS-4HRC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.12 | 3.47 | -20° | 10.00 | 8.70 | |
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
CU-5Z90CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 4.43 | -15° | 9.00 | 8.50 | |
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
AD140S2SM9FA(H)/1U140S2SN2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.30 | 13.40 | 8.50 | ||
|
AD140S2SM9FA(H)/1U140S2SN2FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.30 | 13.40 | 8.50 | ||
|
AOYG45KBTB/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
ROG45KBTB/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ABEG45KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOEG45KBTB/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ABYG45KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOEG54KRTA/ARXH54KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXH54KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXH54KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOHG54KRTA/ARXH54KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
RZA200D
RZA
|
DAIKIN | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.10 | 19.00 | 11.20 | |||
|
AP140S2SE1FA(H)/1U140S2SN2FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 2.75 | 13.40 | 8.50 | ||
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
RAS-5HVNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
ND140MGAHRA/1N140TEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 2.95 | 13.00 | 9.60 | ||
|
AOYG45LATT/AUYG45LRLA
AOYG**L
|
FUJITSU | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOHG45LATT/AUHG45LRLA
AOHG**L
|
GENERAL | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOYG45LATT/AUYG45LRLA
AOYG**L
|
Fujitsu Atlantic | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
AOYG45KRTA/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOHG45KRTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
ROG45KRTA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ABEG45KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOEG45KRTA/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ABYG45KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOYG36LATT/ARYG36LMLA
ARY**L
|
FUJITSU | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.90 | -15° | 10.00 | 10.00 | |
|
AC140S2SK1FA/1U140S2SP2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.60 | 13.60 | 10.00 | ||
|
AC140S2SK1FA(H)/1U140S2SP2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.60 | 13.60 | 10.00 | ||
|
AC140S2SK2FA(H)/1U140S2SP2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.06 | 3.60 | 13.60 | 10.00 | ||
|
FDC125VNA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
AP140S2SK1FA(H)/1U140S2SN2FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 2.75 | 13.40 | 8.50 | ||
|
RAS-5HRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
U7iRT-50/V7iDI-50WiFiR
Ducted R32
|
Inventor | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
AC140S2SK1FA/1U140S2SP2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.06 | 3.50 | 13.60 | 10.00 | ||
|
AC140S2SK1FA(H)/1U140S2SP2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.06 | 3.50 | 13.60 | 10.00 | ||
|
AC140S2SK2FA(H)/1U140S2SP2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.06 | 3.50 | 13.60 | 10.00 | ||
|
RAS-4HVNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.72 | 4.18 | 3.53 | -20° | 10.00 | 8.70 | |
|
MOX630U-48HFN8-RRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-R(GA)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-R-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 |