Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(4)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(20)
CIAT
(9)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(120)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(122)
Fujitsu Atlantic
(59)
GENERAL
(56)
GREE
(4)
GSS
(0)
HAIER
(97)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(42)
IVT
(0)
Inventor
(25)
KAYSUN
(24)
LG
(77)
MIDEA
(125)
MITSUBISHI ELECTRIC
(138)
Mitsubishi Heavy Industries
(190)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(7)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZA200D
RZA
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.79 | 3.90 | 3.90 | 19.00 | 11.20 | ||
|
MXZ-6F120VF2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.99 | 3.28 | -15° | 8.30 | 9.00 | |
|
MXZ-6F120VF3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.14 | 3.99 | 3.28 | -15° | 8.30 | 9.00 | |
|
PUZ-ZM125YDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
AD140S2SM8FA/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.64 | 3.96 | 3.13 | 13.40 | 8.50 | ||
|
AD140S2SM8FA(H)/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.64 | 3.96 | 3.13 | 13.40 | 8.50 | ||
|
AD140S2SM9FA(H)/1U140S2SN1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.64 | 3.96 | 3.13 | 13.40 | 8.50 | ||
|
MOD30U-36HFN8-RRD0W(GA)/MUE-36HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-RRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
FDMX-100N-09M25/YDAX-100H-09T35
FDMX
|
AIRWELL | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
KUE-105 DTR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE2-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(H)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
RPIH-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.28 | 3.70 | 3.29 | -10° | 12.10 | 9.50 | |
|
U7RS-42/V7CI-42WiFiR
Cassette R32
|
Inventor | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
YUKF48BYOEBMO-1/YKKF48BXOEBM-R1
Grande Cassette R32
|
YORK | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 14.00 | 11.00 | |
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
PUZ-ZM125VDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
AC140S2SK1FA/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.00 | 3.02 | 13.40 | 8.50 | ||
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KATA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AC140S2SK1FA/1U140S2SP1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.51 | 13.40 | 11.00 | ||
|
MOE30U-48HFN8-RRD0W(GA)/MTI-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
MOE30U-48HFN8-R(GA)/MTI-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
KUE-140 DTR13/KPD-140 DR13
Zen
|
KAYSUN | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
MOE30U-48HFN8-RRD0W(GA)/MTI-48HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
MO-48N8-R/MTI-48HNX
Duct R32
|
MIDEA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
KUE-140 DTR13/KPD-140 DR14
Zen
|
KAYSUN | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
MOE30U-48HFN8-RRD0W(GA)-GR/MTI-48HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.32 | 3.86 | 3.24 | -10° | 20.00 | 11.40 | |
|
PUZ-M125VKA3/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 4.13 | 3.71 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 4.13 | 3.71 | -15° | 12.10 | 8.50 | |
|
AOYG45KBTB/ARXG45KHTA
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOHG45KBTB/ARXG45KHTA
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KBTB/RDG45KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 |