Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(5)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(4)
IVT
(0)
Inventor
(1)
KAYSUN
(2)
LG
(0)
MIDEA
(5)
MITSUBISHI ELECTRIC
(4)
Mitsubishi Heavy Industries
(73)
NORD
(0)
Nobu
(0)
PANASONIC
(19)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(3)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC250VSA/FDU250VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.82 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
FDC250VSA/FDU250VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.83 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
ADH250H1ERG/1UH250W1ERK
Smart Power - Duct
|
HAIER | Ducted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.97 | 3.50 | 3.43 | 23.50 | 13.00 | ||
|
FDC200VSA/FDU200VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC200VSA/FDU200VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.07 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC140VNX/FDF140VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.80 | 3.57 | 3.41 | 14.00 | 13.00 | ||
|
FDC250VSA-W/FDU250VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.54 | 3.75 | 25.00 | 14.20 | ||
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
FDC140VSX/FDE140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.62 | 3.41 | 14.00 | 15.50 | ||
|
FDC140VNX/FDE140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 3.66 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VSX/FDF140VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.94 | 3.61 | 3.41 | 14.00 | 14.30 | ||
|
FDC200VSA-W/FDU200VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.55 | 3.95 | 20.00 | 13.70 | ||
|
FDC125VSX/FDF125VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.11 | 3.61 | 3.61 | 12.50 | 13.50 | ||
|
ADH200H1ERG/1UH200W1ERK
Smart Power - Duct
|
HAIER | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.82 | 3.43 | 20.50 | 13.00 | ||
|
FDC125VSX/FDTC60VH/FDTC60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.81 | 3.41 | 12.50 | 14.00 | ||
|
PUZ-M200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.48 | 3.61 | 3.40 | -20° | 19.00 | 15.50 | |
|
FDC140VNX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
FDC140VNX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
FDC100VSX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.17 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
FDC140VSX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
PUZ-M200YDA/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.77 | 3.40 | -20° | 19.00 | 15.50 | |
|
U-125PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
FDC100VNX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
FDC140VSX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
U-125PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
U-200PZH4E8 / S-200PE4E
2024
|
PANASONIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.02 | 3.85 | 3.55 | 19.00 | 14.50 | ||
|
FDC140VSX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.88 | 2.63 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDU140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.79 | 3.88 | 2.63 | 14.00 | 15.50 | ||
|
U-140PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDF140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.72 | 3.41 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDF140VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.72 | 3.41 | 14.00 | 15.50 | ||
|
U-140PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
U-140PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.51 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
FDC140VNX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.06 | 3.81 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDF140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.81 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDF140VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.81 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDU140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 | ||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 3.96 | 2.50 | 14.00 | 15.50 | ||
|
U-200PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.41 | 3.89 | 3.71 | -20° | 17.50 | 15.70 | |
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDF125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDF125VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 |