Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(30)
NORD
(0)
Nobu
(0)
PANASONIC
(5)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VSX/FDE125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.74 | 3.66 | 3.71 | 12.50 | 14.00 | ||
|
FDC100VSX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.17 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC100VNX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC125VSX/FDU125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.49 | 3.91 | 3.71 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.04 | 4.08 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.02 | 2.60 | 12.50 | 14.00 | ||
|
U-125PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
U-125PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
FDC140VNX/FDT71VH/FDT71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.35 | 4.28 | 14.00 | 13.00 | ||
|
FDC140VSX/FDT71VH/FDT71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.35 | 4.28 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
FDC200VSA-W/FDT100VH/FDT100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.55 | 4.25 | 20.00 | 12.50 | ||
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
FDC125VSX/FDT60VH/FDT60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.04 | 4.44 | 4.35 | 12.50 | 14.00 | ||
|
FDC125VSX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.94 | 4.36 | 2.91 | 12.50 | 14.00 | ||
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
FDC140VSX-W/FDF71VH1/FDF71VH1
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
FDC140VNX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.76 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDF71VH1/FDF71VH1
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.76 | 14.00 | 13.00 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
FDC140VNX-W/FDT71VH/FDT71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 5.07 | 4.40 | 14.00 | 13.00 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC140VNX-W/FDUM71VH/FDUM71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.21 | 4.92 | 4.10 | 14.00 | 13.00 | ||
|
FDC140VSX-W/FDUM71VH/FDUM71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.21 | 4.68 | 4.10 | 14.00 | 15.50 | ||
|
FDC140VSX-W/FDT71VH/FDT71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.45 | 4.94 | 4.40 | 14.00 | 15.50 | ||
|
U-200PZH4E8 / S-1014PU3E(2x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-6071PU3E(3x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PU3E(4x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 |