Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(3)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(8)
IVT
(0)
Inventor
(2)
KAYSUN
(3)
LG
(0)
MIDEA
(13)
MITSUBISHI ELECTRIC
(2)
Mitsubishi Heavy Industries
(53)
NORD
(0)
Nobu
(0)
PANASONIC
(19)
RIELLO
(2)
Rotenso
(1)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(2)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
U-125PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
U-125PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
U-200PZH4E8 / S-200PE4E
2024
|
PANASONIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.02 | 3.85 | 3.55 | 19.00 | 14.50 | ||
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.36 | 3.95 | 3.33 | -10° | 23.50 | 12.30 | |
|
U-140PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
U-140PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.51 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
42HU60VDS8C/38HU60VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
42QZL060D8S*/38QUS060D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
SC217HIDS8/AIC217HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
RZA250D
RZA
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 3.96 | 2.50 | 14.00 | 15.50 | ||
|
U-200PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.41 | 3.89 | 3.71 | -20° | 17.50 | 15.70 | |
|
MOX630U-55HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.00 | -10° | 15.80 | 12.20 | |
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
RZA250D
RZA
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.44 | 4.10 | 22.00 | 12.10 | |||
|
FDC125VSX-W/FDF125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDF125VH1
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.85 | 3.61 | 12.50 | 14.00 | ||
|
FDC140VNX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
FDC140VSX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
RZA250D
RZA
|
DAIKIN | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.08 | 3.86 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
FDC125VSX/FDT125VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.18 | 4.04 | 4.08 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.02 | 2.60 | 12.50 | 14.00 | ||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.95 | 4.10 | 22.00 | 12.10 | |||
|
42HY60VDS8C/38HU60VDT8C
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
42QSS060D8S*/38QUS060D8T*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
DC217HIDS8/AIC217HIDT8
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
U-250PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.48 | 3.90 | 3.80 | -20° | 22.00 | 16.70 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-125PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
U-125PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
MOE30U-55HFN8-RRD0W(GA)/MTI-55HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
MOE30U-55HFN8-R(GA)/MTI-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
KUE-160 DTR13/KPD-160 DR13
Zen
|
KAYSUN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
MOE30U-55HFN8-RRD0W(GA)/MTI-55HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
MO-55N8-R/MTI-55HNX
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
KUE-160 DTR13/KPD-160 DR14
Zen
|
KAYSUN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7RT-60/V7DI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MTI-55HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7iDI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 |