Filters · 4 active
Manufacturer:
BOSCH
HAIER
Vulcano
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
WESTPOINT
(12)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AB25S2SC2FA(H)/1U25S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
AS35PBAHRA/1U35YEGFRA-2
Wall mounted - Pearl
|
HAIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
AS35PBAHRA/1U35YEGFRA-1
Wall mounted - Pearl
|
HAIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.80 | |
|
AS35PBAHRA-PRO/1U35YEGFRA-PRO
Pearl Pro
|
HAIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
UE-EC 35 / UI-ECU M 35
Easy 3 Cool
|
Vulcano | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
AS25PBAHRA-PRO/1U25YEGFRA-PRO
Pearl Pro
|
HAIER | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
AS25RBAHRA-3/1U25YESFRA-3
Revive Plus
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-PL/1U25YESFRA-3
Revive Plus
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-PL/1U25YESFRA-5
Revive Plus Electric Heater
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-5/1U25YESFRA-5
Revive Plus Electric Heater
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-PC/1U25YESFRA-3
Geos-PT
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-RE/1U25YESFRA-3
Geos-RE
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-TR/1U25YESFRA-TR
Revive Plus
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25RBAHRA-B/1U25YESFRA-3
Wall mounted - R+
|
HAIER | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AC25S2SG2FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
AS25PBBHRA/1U25YEBGRA
Wall mounted - Pearl R290
|
HAIER | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.71 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AD35S2SM9FA(H)/1U35S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 2.70 | |
|
AD25S2SS1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
AS35PBBHRA/1U35YEBGRA
Wall mounted - Pearl R290
|
HAIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 3.61 | -10° | 3.50 | 2.50 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS25PBUHRA/1U25YETFRA
Wall mounted - Pearl Neo
|
HAIER | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25PBUHRA-MT/1U25YETFRA-MT
Wall mounted -Pearl Plus
|
HAIER | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS25S2SF1FA-MW3/1U25MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS25S2SF1FA-MB3/1U25MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS25S2SF1FA-S/1U25S2SM1FA-2
Super Match mono Flexis-Silver
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC25S2SG1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 2.50 | 2.80 | |
|
AB25S2SA1FA/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AB25S2SA1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AD25S2SS1FA/1U25S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
AF25S2SD1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AF25S2SD1FA(D)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AS35PBPHRA-PRE/1U35MEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
AS35S2SF1FA-MW3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS35PBPHRA-PRE/1U35MEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
AS35S2SF1FA-MB3/1U35MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
AS35S2SF1FA-S/1U35S2SM1FA-2
Super Match mono Flexis-Silver
|
HAIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 |