Filters · 4 active
Manufacturer:
BOSCH
Fujitsu Atlantic
GENERAL
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
AOHG12KATA/ARXG12KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG09KATA/ARXG09KLLAP
ARXG**K
|
GENERAL | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AOHG12KATA/AUXG12KVLA
AUXG**K
|
GENERAL | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/AUXG12KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG07KPCA/ASHG07KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG07KPCA/ASHG07KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG09KPCA/ASHG09KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOHG09KPCA/ASHG09KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG09KPCA/ASYG09KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG025KPCA/ASYG025KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AOHG12KPCA/ASHG12KPCE
ASH**L
|
GENERAL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG12KPCA/ASYG12KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG035KPCA/ASYG035KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOHG09KATA/AUXG09KVLA
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AOHH12KLTA/ASHH12KLTA
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AOHH12KLTA/ASHH12KLTBL
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AOHG12KATA/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AOHH09KLTA/ASHH09KLTA
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH09KLTA/ASHH09KLTBL
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH07KLTA/ASHH07KLTA
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHH07KLTA/ASHH07KLTBL
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHG09KMCC/ASHG09KMCE
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA /ASHG09KETE-B
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA /ASHG09KETE
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETE
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETE-B
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KMCC/ASHG09KMCF
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETF
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETF-B
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KETA /ASYG09KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KETA /ASYG09KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KMCC/ASYG09KMCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KETA/ASYG09KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KETA/ASYG09KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KMCC/ASYG09KMCF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 |