Filters · 4 active
Manufacturer:
HITACHI
Vulcano
YORK
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
WESTPOINT
(12)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UE-EC 35 / UI-ECU M 35
Easy 3 Cool
|
Vulcano | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
YHKF12YEEBMJO-X/YHKF12XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
YHKF12YEEBMJO-T/YHKF12XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
YHKF09YEEBMJO-X/YHKF09XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
YHKF09YEEBMJO-T/YHKF09XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
YHKF09YEEGXFO-Y/YHKF09XEEGXF-RY
Altair YHKF
|
YORK | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.03 | 3.75 | -10° | 2.60 | 2.70 | |
|
YHKF12YEEGXFO-Y/YHKF12XEEGXF-RY
Altair YHKF
|
YORK | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.03 | 3.45 | -10° | 3.50 | 2.70 | |
|
RAC-CJ25WHAE / RAK-CJ25PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.71 | -15° | 2.40 | 2.47 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
RAC-CJ35WHAE / RAK-CJ35PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.71 | -15° | 3.20 | 2.80 | |
|
YUKF12BYEEBMO-1/YKKF12BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
RAC-25NPE / RAD-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
RAC-25NPE / RAI-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
YUKF12BYEEBMO-1/YEKF12BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
RAC-35NPE / RAI-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
RAC-35NPE / RAD-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
YHKF12XEEDMH-RY / YHKF12YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
RAC-VJ25NHAE / RAI-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.78 | |
|
RAC-DJ35WHAE / RAK-DJ35RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.00 | -15° | 3.50 | 2.80 | |
|
RAC-DJ25WHAE / RAK-DJ25RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.65 | -15° | 2.50 | 2.47 | |
|
RAC-VJ35NHAE / RAI-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.78 | |
|
YHKF09XEEDMH-RY / YHKF09YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
RAC-VJ25WHAE / RAK-VJ25RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.64 | -15° | 2.50 | 2.47 | |
|
RAC-VJ35WHAE / RAK-VJ35RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.20 | -15° | 3.50 | 2.60 | |
|
RAC-VJ18WHAE / RAK-VJ18RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.82 | -15° | 2.00 | 2.30 | |
|
RAC-25FXE / RAF-25RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.85 | |
|
RAC-25WXEN / RAK-25RXE
RAC-WXEN
|
HITACHI | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.20 | 5.40 | -20° | 2.50 | 2.18 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAC-XJ25WHAE / RAK-XJ25RHAE
RAC-XJ-WHAE airHome 800
|
HITACHI | Wall mounted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 5.40 | -20° | 2.50 | 2.18 | |
|
RAC-XJ25WHBE / RAK-XJ25RHBE
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 5.40 | -20° | 2.50 | 2.18 | |
|
RAC-XJ25WHBE / RAK-XJ25RHBEG
RAC-XJ-WHBE airHome 800
|
HITACHI | Wall mounted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.20 | 5.40 | -20° | 2.50 | 2.18 | |
|
RAC-XJ25FHAE / RAF-XJ25RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.77 |