Filters · 3 active
Manufacturer:
ATLANTIC
MITSUBISHI ELECTRIC
AIRCLASS
(2)
AIRWELL
(26)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-HJ35VA/MSZ-HJ35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.62 | -10° | 3.10 | 2.40 | |
|
SUZ-M25VA/SFZ-M25VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SFZ-M25VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
UI 2,7KW MURAO ACCESS BLANC/UE MONO 2,7KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
MXZ-2F33VF4/MSZ-AY15VGK/MSZ-LN18VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 4.40 | -15° | 3.30 | 2.70 | |
|
MXZ-2F33VF5/MSZ-AY15VGK(P)2/MSZ-LN18VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 4.40 | -15° | 3.30 | 2.70 | |
|
MUZ-DM35VA/MSZ-DM35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 4.10 | 3.69 | -10° | 3.10 | 2.40 | |
|
SUZ-M35VA/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 2.60 | |
|
SUZ-M35VA/SFZ-M35VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SFZ-M35VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
AS 009 DBB.UI/ 1U 009 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.71 | -10° | 2.60 | 2.40 | |
|
PUZ-ZM35VKA2/PKA-M35LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PKA-M35LAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
MXZ-2D33VA/MSZ-SF15VA/MSZ-EF18VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 4.10 | 4.17 | -15° | 3.30 | 2.70 | |
|
MUZ-HR25VF2/MSZ-HR25VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.71 | -10° | 2.50 | 2.00 | |
|
MUZ-HR35VF/MSZ-HR35VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-DW35VF/MSZ-DW35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-HR35VF2/MSZ-HR35VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -10° | 3.40 | 2.40 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
SUZ-M25VA/MFZ-KT25VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 2.50 | 2.20 | |
|
MUZ-HR42VF/MSZ-HR42VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.62 | -10° | 4.20 | 2.90 | |
|
MUZ-HR42VF2/MSZ-HR42VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.62 | -10° | 4.20 | 2.90 | |
|
SUZ-M25VA/SEZ-M25DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/SEZ-M25DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SEZ-M25DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
AS 009 NBB.UI/1U 009 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
PUZ-ZM35VKA3/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.70 | |
|
SUZ-SM35VA2/PEAD-SM35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.70 | |
|
MUZ-WN35VA/MSZ-WN35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -15° | 3.10 | 2.40 | |
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
SUZ-SM35VA/PEAD-SM35JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
SUZ-SM35VA/PEAD-SM35JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
SUZ-M25VA2/MFZ-KT25VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 2.50 | 2.20 | |
|
AS 012 NBB.UI/1U 012 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
UI 3,6 kW MURAO SMART BLANC & UE MONO 3,6 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
MUZ-SF35VE/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.88 | -15° | 3.50 | 2.90 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
SUZ-M35VA/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
MUZ-BT35VG2/MSZ-BT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.50 | |
|
UI 2,7 kW MURAO SMART BLANC & UE MONO 2,7 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
MUZ-SF25VE/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.40 | 4.10 | -15° | 2.50 | 2.40 | |
|
MUZ-BT35VG/MSZ-BT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.40 | |
|
SUZ-M25VA/SLZ-M25FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SLZ-M25FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
MUZ-SF25VEH/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.10 | -20° | 2.50 | 2.40 |