Filters · 4 active
Manufacturer:
Fujitsu Atlantic
PANASONIC
TOSHIBA
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(42)
BOSCH
(48)
BRYANT
(4)
Buderus
(14)
CARRIER
(48)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
DE DIETRICH
(9)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
GENERAL
(89)
GREE
(44)
GSS
(2)
HAIER
(96)
HEC
(3)
HEIWA
(3)
HISENSE
(162)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(18)
LG
(118)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PITSOS
(4)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
XTRON
(2)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM561ATP-E1/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 4.00 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GM301ATP-E/RAV-HM301KRTP-E
DI
|
TOSHIBA | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.69 | 3.96 | 4.00 | -15° | 2.50 | 2.60 | |
|
RAV-GM562ATP-E/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 4.01 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GM302ATP-E/RAV-HM301U1TP-E
DI
|
TOSHIBA | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.54 | 3.96 | 3.30 | -15° | 2.50 | 2.60 | |
|
RAV-GV561ATP-E/RAV-HM561KRTP-E
DIC
|
TOSHIBA | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.90 | 3.53 | -15° | 5.00 | 2.80 | |
|
RAV-GM302ATP-E/RAV-HM301KRTP-E
DI
|
TOSHIBA | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.26 | 3.98 | 4.00 | -15° | 2.50 | 2.60 | |
|
RAS-07B2AVG-E2/RAS-B07B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-07B2AVG-E2/RAS-B07B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-13B2AVG-E2/RAS-B13B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.53 | -15° | 3.30 | 2.30 | |
|
RAS-13LAV2G-E/RAS-B13LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.53 | -15° | 3.30 | 2.30 | |
|
RAS-13B2AVG-E2/RAS-B13B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.53 | -15° | 3.30 | 2.30 | |
|
RAS-10B2AVG-E2/RAS-B10B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.81 | -15° | 2.50 | 2.10 | |
|
RAS-10B2AVG-E2/RAS-B10B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.81 | -15° | 2.50 | 2.10 | |
|
RAS-10LAV2G-E/RAS-B10LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.81 | -15° | 2.50 | 2.10 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
RAV-GM561ATP-E1/RAV-HM561KRTP-E
DI
|
TOSHIBA | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.31 | 4.00 | 3.42 | -15° | 5.00 | 2.80 | |
|
RAV-GM402ATP-E/RAV-HM401U1TP-E
DI
|
TOSHIBA | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.03 | -15° | 3.60 | 2.70 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
RAV-GV561ATP-E/RAV-HM561BTP-E
DIC
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 3.21 | -15° | 5.00 | 2.80 | |
|
AOYG12KATA/AUXG12KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
CU-PZ35WKE / CS-PZ35WKE
2019
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.69 | -15° | 3.40 | 2.40 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG09KPCA/ASYG09KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG025KPCA/ASYG025KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
CU-UZ35WKE / CS-UZ35WKE
2019
|
PANASONIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.70 | -15° | 3.30 | 2.40 | |
|
CU-UZ35ZKE / CS-UZ35ZKE
2023
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
RAV-GM562ATP-E/RAV-HM561KRTR-E
DI
|
TOSHIBA | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.69 | 4.02 | 3.42 | -15° | 5.00 | 2.80 | |
|
AOYG12KPCA/ASYG12KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG035KPCA/ASYG035KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
RAS-13B2AVG-E2/RAS-B13B2KVG-E3
SEIYA
|
TOSHIBA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
CU-UZ35CKE / CS-UZ35CKE
2025
|
PANASONIC | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
CU-FZ35WKE / CS-FZ35WKE
2019
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.66 | -15° | 3.40 | 2.40 | |
|
CU-BZ35XKE / CS-BZ35XKE
2022
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.69 | -15° | 3.40 | 2.40 | |
|
AOYG12KATA/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
RAV-GM401ATP-E/RAV-HM401KRTP-E
DI
|
TOSHIBA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 4.22 | 3.57 | -15° | 3.60 | 2.70 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
CU-BZ35ZKE / CS-BZ35ZKE
2023
|
PANASONIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
CU-BZ35CKE / CS-BZ35CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
U-25PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 4.52 | -15° | 2.50 | 2.50 | |
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
CU-UZ25CKE / CS-UZ25CKE
2025
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.06 | -15° | 2.50 | 2.10 | |
|
RAV-GM402ATP-E/RAV-HM401KRTP-E
DI
|
TOSHIBA | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.24 | 3.57 | -15° | 3.60 | 2.70 | |
|
AOYG09KETA /ASYG09KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KETA /ASYG09KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KMCC/ASYG09KMCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYG09KETA/ASYG09KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 |