Filters · 4 active
Manufacturer:
DAIKIN
THERMOR
WESTPOINT
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
YORK
(10)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
NAGANO CASSETTE IK26-F66-NG/E1U26LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
NISEKO MURALE IM35-NS / E1U35L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
NISEKO MURALE IM20-NS / E1U20L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
NISEKO MURALE IM26-NS / E1U26L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
RXM35R9 / FDXM35F9
RXM
|
DAIKIN | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.26 | 3.88 | 3.48 | -15° | 3.40 | 2.90 | |
|
NAGANO GAINABLE BP IG25BP-NG/E1U26LV2-NG
NAGANO GAINABLE BASSE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
WIZO-12225.MH / WIZ-12225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
ARXQ35A / ATXQ35A
ARXQ
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.11 | 3.71 | -10° | 3.50 | 2.40 | |
|
ARXQ25A / ATXQ25A
ARXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.15 | 3.71 | -10° | 2.50 | 2.30 | |
|
RXQ35A / FTXQ35A
RXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.12 | 3.71 | -10° | 3.50 | 2.40 | |
|
WIZO-09225.MH / WIZ-09225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
RXQ25A / FTXQ25A
RXQ
|
DAIKIN | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 4.22 | 3.71 | -10° | 2.50 | 2.30 | |
|
ARXF35E / ATXF35E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -15° | 3.50 | 2.60 | |
|
ARXF25E / ATXF25E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 2.50 | 2.40 | |
|
ARXF20E / ATXF20E
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF20F / ATXF20F
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF35F / ATXF35F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
ARXF25F / ATXF25F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
ARXM35R9 / ADEA35A
ARXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 4.00 | 3.97 | -15° | 3.40 | 2.90 | |
|
RXF35E / FTXF35E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
RXF35F / FTXF35F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
RXF25E / FTXF25E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF25F / FTXF25F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF20E / FTXF20E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
RXF20F / FTXF20F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXC35D / ATXC35D
ARXC
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 4.26 | 3.72 | -14° | 3.44 | 2.24 | |
|
RXC35D / FTXC35D
RXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.87 | 4.28 | 3.74 | -14° | 3.44 | 2.24 | |
|
ARXC35E / ATXC35E
ARXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.72 | -14° | 3.40 | 2.20 | |
|
RXC35E / FTXC35E
RXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.74 | -14° | 3.40 | 2.20 | |
|
ARXC25E / ATXC25E
ARXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.40 | 3.76 | -14° | 2.60 | 2.20 | |
|
NAGANO CONSOLE IC26V3-NG / E1U26LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
RXM35R9 / FNA35A9
RXM
|
DAIKIN | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.05 | 3.48 | -15° | 3.40 | 2.90 | |
|
ARXC25D / ATXC25D
ARXC
|
DAIKIN | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.41 | 3.76 | -14° | 2.57 | 2.23 | |
|
RXC25E / FTXC25E
RXC
|
DAIKIN | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.50 | 3.79 | -14° | 2.60 | 2.20 | |
|
RXC25D / FTXC25D
RXC
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.45 | 3.79 | -14° | 2.57 | 2.23 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
ARXP25N / ATXP25N
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
ARXP25N9 / ATXP25N9
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
RZAG35B / FTXM35A
RZAG
|
DAIKIN | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 3.85 | -10° | 3.50 | 2.60 | |
|
NAGANO U.I 3500W R32 / E1U35LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE IM35V2-NG / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE NOIRE IM35V2-NGN / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE IM35V3-NG / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE NOIRE IM35V3-NGN / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
WITO-12322.MH/WIT-12322.MH
WIT
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WIMO-12325.MH / WIM-12325.MH
WIM 325
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
ARXP35N / ATXP35N
ARXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.62 | 4.02 | -15° | 3.50 | 2.80 | |
|
ARXP35N9 / ATXP35N9
ARXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.62 | 4.02 | -15° | 3.50 | 2.80 |