Filters · 4 active
Manufacturer:
GENERAL
THERMOR
WESTPOINT
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
NAGANO CASSETTE IK26-F66-NG/E1U26LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
NISEKO MURALE IM35-NS / E1U35L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
NISEKO MURALE IM20-NS / E1U20L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
NISEKO MURALE IM26-NS / E1U26L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
AOHG12KATA/ARXG12KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG09KATA/ARXG09KLLAP
ARXG**K
|
GENERAL | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
NAGANO GAINABLE BP IG25BP-NG/E1U26LV2-NG
NAGANO GAINABLE BASSE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
WIZO-12225.MH / WIZ-12225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
AOHG12KATA/AUXG12KVLA
AUXG**K
|
GENERAL | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG07KPCA/ASHG07KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG07KPCA/ASHG07KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG09KPCA/ASHG09KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOHG09KPCA/ASHG09KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
WIZO-09225.MH / WIZ-09225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
AOHG12KPCA/ASHG12KPCE
ASH**L
|
GENERAL | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOHG09KATA/AUXG09KVLA
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHH12KLTA/ASHH12KLTA
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AOHH12KLTA/ASHH12KLTBL
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AOHG12KATA/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHH09KLTA/ASHH09KLTA
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH09KLTA/ASHH09KLTBL
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH07KLTA/ASHH07KLTA
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHH07KLTA/ASHH07KLTBL
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHG09KMCC/ASHG09KMCE
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA /ASHG09KETE-B
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA /ASHG09KETE
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETE
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETE-B
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KMCC/ASHG09KMCF
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETF
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG09KETA/ASHG09KETF-B
ASH**K
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHG07KETA /ASHG07KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA /ASHG07KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KMCC/ASHG07KMCE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KMCC/ASHG07KMCF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHG07KETA/ASHG07KETF-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.10 | 4.52 | -15° | 2.00 | 2.30 | |
|
NAGANO CONSOLE IC26V3-NG / E1U26LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AOHH12KNCA/ASHH12KNCA
ASH**K
|
GENERAL | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
AOHH12KNCA/ASHH12KNCH
ASH**K
|
GENERAL | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.73 | -15° | 3.40 | 2.50 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AOHG12KETA /ASHG12KETE
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA /ASHG12KETE-B
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KMCC/ASHG12KMCE
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETE
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETE-B
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KMCC/ASHG12KMCF
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOHG12KETA/ASHG12KETF
ASH**K
|
GENERAL | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 |