Filters · 4 active
Manufacturer:
CARRIER
RIELLO
Viessmann
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
42QHA012D8S*/38QHA012D8S*
Wall mounted
|
CARRIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.38 | -10° | 3.68 | 2.70 | |
|
WR035HJM8/AIR035HJM8
Wall mounted
|
RIELLO | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.38 | -10° | 3.68 | 2.70 | |
|
42QHF012D8S*/38QHF012D8S*
Wall mounted
|
CARRIER | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.38 | -10° | 3.68 | 2.70 | |
|
42QHA009D8S*/38QHA009D8S*
Wall mounted
|
CARRIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
WR025HJM8/AIR025HJM8
Wall mounted
|
RIELLO | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
42QHF009D8S*/38QHF009D8S*
Wall mounted
|
CARRIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
38WHSS020ATA0TEE/40WHSW020DTA0TEE
40WHS
|
CARRIER | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSS025ATA0TEE/40WHSW025DTA0TEE
40WHS
|
CARRIER | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.81 | -15° | 2.50 | 2.10 | |
|
42QHG012D8SJ-2/38QHG012D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.50 | -10° | 3.50 | 2.80 | |
|
42QHG012D8SJ-B/38QHG012D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.50 | -10° | 3.50 | 2.80 | |
|
42QTD009D8SN*/38QUS009D8SX*
Cassette
|
CARRIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
Vitoclima100-SIC8AA100MFA027/Vitoclima100-SPROOFAA100MFP027
Cassette
|
Viessmann | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
42QHA012D8S3/38QHA012D8S3
Wall mounted
|
CARRIER | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
WR035HJM8-W/AIR035HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
Vitoclima 050-S IWAA050MFA035/Vitoclima 050-S OWAA050MFA035
Wall mounted
|
Viessmann | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
38WHSS035ATA0TEE/40WHSW035DTA0TEE
40WHS
|
CARRIER | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
42QHG009D8SJ-2/38QHG009D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
42QHA009D8S3/38QHA009D8S3
Wall mounted
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
WR025HJM8-W/AIR025HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
Vitoclima 050-S IWAA050MFA026/Vitoclima 050-S OWAA050MFA026
Wall mounted
|
Viessmann | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
42QHG009D8SJ-B/38QHG009D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
42QHG009D8S*/38QHG009D8S*
Wall mounted
|
CARRIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.85 | -10° | 2.75 | 2.50 | |
|
WR525HJM8*/AIR525HJM8*
Wall mounted
|
RIELLO | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.85 | -10° | 2.75 | 2.50 | |
|
42QHG012D8S*/38QHG012D8S*
Wall mounted
|
CARRIER | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
WR535HJM8*/AIR535HJM8*
Wall mounted
|
RIELLO | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
DC235HIDS8/AIC235HIDS8
Ducted
|
RIELLO | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
42QSS012D8S*/38QUS012D8S*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
38WHSM035A1A0TEE/40WHMW035D1A0TEE
40WHM
|
CARRIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.14 | -15° | 3.30 | 2.70 | |
|
42QTD012D8SN*/38QUS012D8S-1
Cassette
|
CARRIER | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
Vitoclima100-SIC8AA100MFA035/Vitoclima100-SPROOFAA100MFP035
Cassette
|
Viessmann | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
KC235HIDS8/AIC235HIDS8
Cassette
|
RIELLO | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
42QTD012D8S*/38QUS012D8S*
Cassette
|
CARRIER | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
42QHG012D8SH*/38QHG012D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WR235HJM8-1/AIR235HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
42QCE009D8SH*/38QCE009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.50 | 2.60 | |
|
42QCE012D8SH*/38QCE012D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.52 | 2.60 | |
|
42QCE012D8SH/38QCE012D8SH
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
42QHE12D8SH*/38QHE12D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -10° | 3.50 | 2.40 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QCE009D8SH/38QCE009D8SH
Wall mounted
|
CARRIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
42QHG009D8SH*/38QHG009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
WR225HJM8-1/AIR225HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
42QHE09D8SH*/38QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 4.60 | 4.51 | -10° | 2.64 | 2.40 | |
|
42QSV012D8S*/38QUS012D8S-1
Ducted
|
CARRIER | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 |