Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HEIWA
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(93)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS35XV04W/QH35XV4BG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV04W/QH35XV3AG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV4AW/QH35XV4AG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV4FW/QH35XV4AG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV4FW/QH35XV4BG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV4FW/QE35XV4EG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV4AW/QH35XV4BG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
AS35XV4AW/QH35XV3AG
Energy Pro X
|
HISENSE | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.00 | -10° | 3.50 | 2.60 | |
|
UUA1 UL0 / UV18F N10
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 3.70 | -10° | 5.00 | 2.90 | |
|
MOX230-12HFN8-QRD0W(GA)/MTJ-12HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MTJU-12HNX
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KPD-35 DR15
Duct R32
|
KAYSUN | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
DDMD-035N-09M25/YDAX-035H-09M25**
DDMD
|
AIRWELL | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
42QSV012D8S*/38QUS012D8S-1
Ducted
|
CARRIER | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7iDI-12WiFiR
Ducted R32
|
Inventor | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CU-Z20XKE / CS-Z20XKEW
2021
|
PANASONIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
CU-Z20XKE / CS-XZ20XKEW
2021
|
PANASONIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
MUZ-AY35VGH/MSZ-AY35VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUZ-AY35VGH2/MSZ-AY35VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.88 | -20° | 3.50 | 2.90 | |
|
RAV-GM561ATP-E1/RAV-HM561UTP-E
DI
|
TOSHIBA | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.60 | 3.90 | -15° | 5.00 | 2.80 | |
|
MUZ-EF35VG/MSZ-EF35VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.21 | -15° | 3.50 | 2.90 | |
|
MUZ-EF35VG2/MSZ-EF35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.21 | -15° | 3.50 | 2.90 | |
|
AS35S2SJ1FA-3/1U35MECFRA-3
Super Match mono-Jade Plus
|
HAIER | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
AS 012 JDB.UI/ 1U 012 JD.UE
Kazendo
|
ATLANTIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
MUZ-EF25VE/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.57 | -15° | 2.50 | 2.40 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
U-25PZ3E5 / S-25PY3E
2022
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -15° | 2.50 | 2.80 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
U-36PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.61 | -15° | 3.50 | 2.80 | |
|
EQO-09/EQI-09WFI
Econ IQ
|
Inventor | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.70 | 4.30 | -10° | 2.60 | 2.50 | |
|
RAC-VJ25WHAE / RAK-VJ25RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.64 | -15° | 2.50 | 2.47 | |
|
RAC-VJ35WHAE / RAK-VJ35RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.20 | -15° | 3.50 | 2.60 | |
|
AS25XCAHRA/1U25S2SM1FA-2
Wall mounted - EXPERT
|
HAIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.75 | 4.20 | -10° | 2.80 | 2.50 | |
|
AS25XCAHRA/1U25MEHFRA-1
Expert electric heater
|
HAIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.75 | 4.20 | -10° | 2.80 | 2.50 | |
|
AS25XCAHRA-MB/1U25MEHFRA-1
Expert electric heater
|
HAIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.75 | 4.20 | -10° | 2.80 | 2.50 | |
|
AS25XCAHRA-MB/1U25S2SM1FA-2
Wall mounted - EXPERT
|
HAIER | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.75 | 4.20 | -10° | 2.80 | 2.50 | |
|
RAS-25G3AVSG-ND/RAS-B25N4KVRG-ND
HAORI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
RAS-25G3AVSG-ND/RAS-B25G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 5.10 | 4.92 | -25° | 2.80 | 2.70 | |
|
AR12TXCACWKN/AR12TXCACWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 |