Filters · 4 active
Manufacturer:
AIRCLASS
PANASONIC
SAMSUNG
AIRWELL
(21)
ATLANTIC
(9)
AUX
(21)
BOSCH
(41)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
LG
(75)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
RIELLO
(11)
Rotenso
(0)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
AR70F18C1DBN/AR70F18C1DBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80F18CAAWN/AR80F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80H18CAAWN/AR80H18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR70H18CACBN/AR70H18CACBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
CU-TZ42WKE / CS-TZ42WKEW
2019
|
PANASONIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -15° | 4.20 | 3.60 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
CU-FZ60WKE / CS-FZ60WKE
2019
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.15 | -15° | 6.00 | 4.40 | |
|
CU-BZ60XKE / CS-BZ60XKE
2022
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.16 | -15° | 6.00 | 4.40 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
AR18BXHQASIN / AR18BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -10° | 5.30 | 4.20 | |
|
CU-TZ42ZKE / CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 4.20 | 3.60 | |
|
CU-TZ42CKE / CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.73 | -15° | 4.20 | 3.60 | |
|
AC071RXADKG/AC071BNLDKG
CAC
|
SAMSUNG | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.36 | -20° | 7.10 | 3.70 | |
|
CU-UZ50WKE / CS-UZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-FZ50WKE / CS-FZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-BZ50XKE / CS-BZ50XKE
2022
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 4.70 | 4.00 | |
|
CU-UZ50ZKE / CS-UZ50ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0BMN/AR40F18C0BMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
CU-UZ50CKE / CS-UZ50CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-BZ60ZKE / CS-BZ60ZKE
2023
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.16 | -15° | 6.00 | 4.40 | |
|
CU-BZ60CKE / CS-BZ60CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.16 | -15° | 6.00 | 4.40 | |
|
CU-BZ50ZKE / CS-BZ50ZKE
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-BZ50CKE / CS-BZ50CKE
2025
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.42 | -15° | 5.00 | 4.00 | |
|
AR50F18C1AHN/AR50F18C1AHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR50F18C1BHN/AR50F18C1BHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
CU-Z42XKE / CS-Z42XKEW
2021
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.68 | -15° | 4.20 | 3.60 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
AR50F24C1AHN/AR50F24C1AHX
RAC
|
SAMSUNG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR50F24C1BHN/AR50F24C1BHX
RAC
|
SAMSUNG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR70F18C1AWN/AR70F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1AWN/AR60F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18CAAWN/AR60F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1KWN/AR60F18C1KWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18C1AWN/AR70H18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18CACWN/AR70H18CACWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
CU-Z60UBEA / CS-Z60UB4EAW
2017
|
PANASONIC | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 2.92 | -15° | 6.00 | 4.00 | |
|
CU-2TZ41TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 4.49 | -15° | 4.10 | 3.50 | |
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
AR70F24C1AWN/AR70F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1AWN/AR60F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24CAAWN/AR60F24CAAWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1KWN/AR60F24C1KWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR70F24C1DBN/AR70F24C1DBX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.15 | -11° | 6.50 | 4.10 |