Filters · 8 active
Manufacturer:
AIRCLASS
BOSCH
COLIBRI
FUJITSU
TOSHIBA
Vulcano
WESTPOINT
AIRWELL
(21)
ATLANTIC
(9)
AUX
(35)
BRYANT
(1)
Buderus
(8)
CARRIER
(44)
CIAT
(11)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
DE DIETRICH
(8)
EQUATION
(0)
FUJI ELECTRIC
(38)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(51)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(95)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(10)
LG
(77)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
PITSOS
(1)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
Viessmann
(5)
XTRON
(1)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
RAS-16B2AVG-E2/RAS-B16B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16B2AVG-E2/RAS-B16B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16LAV2G-E/RAS-B16LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
RAS-18B2AVG-E2/RAS-B18B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18B2AVG-E2/RAS-B18B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-18LAV2G-E/RAS-B18LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.23 | -15° | 5.00 | 3.70 | |
|
RAS-24B2AVG-E2/RAS-B24B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24B2AVG-E2/RAS-B24B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
RAS-24LAV2G-E/RAS-B24LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 6.50 | 4.40 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG22KATA/ARXH22KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXH22KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
COLI18R8SHF/COLI18R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 |