Filters · 9 active
Manufacturer:
AIRCLASS
AUX
BOSCH
COLIBRI
Candy
SAMSUNG
WESTPOINT
YORK
AIRWELL
(21)
ATLANTIC
(9)
BRYANT
(1)
Buderus
(8)
CARRIER
(44)
CIAT
(11)
CONFORT AIR
(1)
DAIKIN
(170)
DE DIETRICH
(8)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(51)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(95)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(10)
LG
(77)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
PITSOS
(1)
RIELLO
(11)
Rotenso
(0)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
XTRON
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CY-12RAIN-A/CY-12RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
CY-2M14AOUT-A/CY-09QBIN-A/CY-12QBIN-A
Pearl Premium-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
CY-2T14AOUT-A/CY-09RAIN-MA/CY-12RAIN-MA
Revive plus-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.80 | -10° | 4.00 | 3.30 | |
|
CY-18RBW-IN/CY-18RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
CY-18RAIN-A/CY-18RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.71 | -10° | 4.80 | 3.60 | |
|
AL-H18/4DR3HB3(U) / AUCO-H18/4DR3HA2
Console
|
AUX | Console | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.31 | -10° | 4.70 | 3.70 | |
|
RXYL52M-T1B/FDCO52-B
Console
|
AUX | Console | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.31 | -10° | 4.70 | 3.70 | |
|
YHKF18YEEGXFO-X/YHKF18XEEGXF-RX
Altair YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.71 | -10° | 5.10 | 3.30 | |
|
ASW-H18E0D4/ZAR3DI-C0 / ASW-H18E0D4/ZAR3DI-C0
Z SERIES
|
AUX | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
ASW-H18E0E4/ZAR3DI-C0 / ASW-H18E0E4/ZAR3DI-C0
Z SERIES
|
AUX | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
ASW-H18E2B4/QAR3DI-C0 / ASW-H18E2B4/QAR3DI-C0
Q SERIES
|
AUX | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
ASW-H18E2B4/QCR3DI-C0 / ASW-H18E2B4/QCR3DI-C0
Q SERIES
|
AUX | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
RTX52MQH-T1B/FTXM52QH-B
Q SERIES
|
AUX | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.15 | -10° | 5.10 | 3.30 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3A(C*)X2
C SERIES
|
AUX | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.91 | -10° | 3.80 | 3.40 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(Q*)X2
Q-smart
|
AUX | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.04 | 2.55 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3B(Q*)X2
Q-smart
|
AUX | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.04 | 3.91 | -10° | 4.10 | 3.70 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
ASW-H18E3G4/JAR3DI-C0 / ASW-H18E3G4/JAR3DI-C0
J SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
ASW-H18E3G4/QCR3DI-C0 / ASW-H18E3G4/QCR3DI-C0
Q SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.10 | -10° | 5.30 | 3.90 | |
|
ASW-H18E3H4/JAR3DI-C0 / ASW-H18E3H4/JAR3DI-C0
J SERIES
|
AUX | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.11 | -10° | 5.30 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AR70F18C1DBN/AR70F18C1DBX
RAC
|
SAMSUNG | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80F18CAAWN/AR80F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80H18CAAWN/AR80H18CAAWX
RAC
|
SAMSUNG | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR70H18CACBN/AR70H18CACBX
RAC
|
SAMSUNG | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(H*)X2
Halo
|
AUX | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.03 | 3.72 | -10° | 5.40 | 4.40 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(Q*)X2
Q-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.13 | 4.04 | 2.81 | -10° | 5.40 | 4.40 | |
|
AM2-H18/4DR3C + AMWM-H09/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.04 | 3.72 | -10° | 5.40 | 4.40 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(H*)X2
Halo
|
AUX | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.97 | 4.15 | 4.21 | -10° | 4.10 | 3.70 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
YHKF18XEEBMH-RY / YHKF18YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.65 | -10° | 5.30 | 4.10 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
YUKF18BYEEBMO-1/YKKF18BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AM2-H14/4DR3C + AMWM-H07/4R3A(J*)x2
J-smart
|
AUX | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.18 | 4.13 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AM2-H14/4DR3C+AMWM-H07/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
RXYM42M(2)-T1B+FTXM21CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.48 | 4.10 | 3.91 | -10° | 4.10 | 3.70 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
AR18BXHQASIN / AR18BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -10° | 5.30 | 4.20 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-X/YHKF18XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-T/YHKF18XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 |