Filters · 8 active
Manufacturer:
BOSCH
COLIBRI
Candy
DAIKIN
THERMOR
Vulcano
WESTPOINT
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(35)
BRYANT
(1)
Buderus
(8)
CARRIER
(44)
CIAT
(11)
CONFORT AIR
(1)
DE DIETRICH
(8)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GENERAL
(62)
GREE
(51)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(95)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(10)
LG
(77)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
PITSOS
(1)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
TOSHIBA
(77)
Viessmann
(5)
XTRON
(1)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
NAGANO CASSETTE IK35-F66-NG / E1U35LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
RXM50A9 / FFA50A9
RXM
|
DAIKIN | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -10° | 5.00 | 3.84 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
CY-12RAIN-A/CY-12RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
RXM50A8 / FFA50A9
RXM
|
DAIKIN | Cassette | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.86 | 3.36 | -15° | 5.00 | 3.84 | |
|
NAGANO U.I 2600W R32+NAGANO U.I 3500W R32/NAGANO U.E BI 4000W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM26V2-NG + IM35V2-NG/NAGANO U.E BI 4000W R32
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
CY-2M14AOUT-A/CY-09QBIN-A/CY-12QBIN-A
Pearl Premium-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
CY-2T14AOUT-A/CY-09RAIN-MA/CY-12RAIN-MA
Revive plus-Multisplit
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.80 | -10° | 4.00 | 3.30 | |
|
5MWXM68A9 / FBA35A9 / FBA35A9
5MWXM
|
DAIKIN | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.29 | -15° | 6.80 | 3.60 | |
|
RXM50A9 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.92 | 3.86 | 3.35 | -10° | 5.00 | 4.35 | |
|
CY-18RBW-IN/CY-18RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
RXM50R / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
RXM50A / FFA50A9
RXM
|
DAIKIN | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.98 | 3.90 | 3.49 | -15° | 5.00 | 3.84 | |
|
NISEKO MURALE IM42-NS / E1U42L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
CY-18RAIN-A/CY-18RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.71 | -10° | 4.80 | 3.60 | |
|
RXM50A8 / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.84 | 3.82 | 3.23 | -15° | 5.00 | 4.35 | |
|
4MXM68A9 / FBA35A9 / FBA35A9
4MXM
|
DAIKIN | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.26 | 3.81 | 3.24 | -15° | 6.80 | 3.60 | |
|
3MXM68A9 / FBA35A9 / FBA35A9
3MXM
|
DAIKIN | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.42 | 3.81 | 3.24 | -15° | 6.80 | 3.60 | |
|
RXM50R / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RXM50A / FHA50A9
RXM
|
DAIKIN | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.86 | 3.35 | -15° | 5.00 | 4.35 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
RXM50A8 / FDXM50F9
RXM
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.89 | 2.99 | -15° | 5.00 | 4.00 | |
|
RZAG50B / FDXM50F9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
RZAG50B / FNA50A9
RZAG
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.40 | -10° | 5.00 | 4.30 | |
|
5MWXM68A9 / FTXM42A / FTXM25A
5MWXM
|
DAIKIN | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.85 | 3.24 | -15° | 6.70 | 4.30 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
RXM50A9 / FDXM50F9
RXM
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.93 | 3.10 | -10° | 5.00 | 4.00 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
RZAG35B / FDXM35F9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35B / FNA35A9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
NAGANO UI MURALE 4200W R32 / NAGANO U.E MONO 4200W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V2-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V2-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V3-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V3-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
RXM60R / FFA60A9
RXM
|
DAIKIN | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.76 | 4.04 | 3.41 | -15° | 5.70 | 3.96 | |
|
2MXM68A9 / FTXM42R / FTXM25R
2MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
3MXM68A9 / FTXM25R / FTXM42R
3MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
4MXM68A9 / FTXM25R / FTXM42R
4MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
2MXM68A9 / FTXM42A / FTXM25A
2MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
3MXM68A9 / FTXM25A / FTXM42A
3MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 | |
|
4MXM68A9 / FTXM25A / FTXM42A
4MXM
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.94 | 3.86 | 3.95 | -15° | 6.70 | 4.30 |