Filters · 3 active
Manufacturer:
Candy
GENERAL
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(21)
BOSCH
(41)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
LG
(75)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CY-12RAIN-A/CY-12RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
CY-2M14AOUT-A/CY-09QBIN-A/CY-12QBIN-A
Super Match Multi
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
CY-2T14AOUT-A/CY-09RAIN-MA/CY-12RAIN-MA
Super Match Multi
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.80 | -10° | 4.00 | 3.30 | |
|
CY-18RBW-IN/CY-18RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
AOHG14KATA/ARXG14KLLAP
ARXG**K
|
GENERAL | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
CY-18RAIN-A/CY-18RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.71 | -10° | 4.80 | 3.60 | |
|
AOHG22KATA/ARXG22KMLA
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/ARXG22KMLB
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/AUXG18KVLA
AUXG**K
|
GENERAL | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOHG22KATA/AUXG22KVLA
AUXG**K
|
GENERAL | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/ARXG18KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOHG14KATA/AUXG14KVLA
AUXG**K
|
GENERAL | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KBTB/ARXG14KLLAP
ARH**K
|
GENERAL | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG22KATA/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOHG14KVCA/AGHG14KVCA
AGH**K
|
GENERAL | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOHG22KATA/AUXG22KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/AUXG18KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOHG14KETA /ASHG14KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA /ASHG14KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KMCC/ASHG14KMCF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETF-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCG
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCG-B
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCH-B
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCH
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KBTB/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG12KBTB/ARXG12KLLAP
ARH**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KVCA/AGHG12KVCA
AGH**K
|
GENERAL | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOHG14KBTB/ARXG14KHTAP
ARH**K
|
GENERAL | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOHH14KACB2/ASHH07KLTBL/ASHH07KLTBL
AOH**K Multi
|
GENERAL | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.30 | 4.33 | -15° | 4.00 | 3.30 | |
|
AOHG18KBTB/ABHG18KRTA
ABH**K
|
GENERAL | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/AUXG18KVLA
AUH**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
AOHH18KACB2/ASHH09KLTBL/ASHH09KLTBL
AOH**K Multi
|
GENERAL | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.30 | 3.73 | -15° | 5.00 | 3.50 | |
|
AOHH18KACB3/ASHH09KLTBL/ASHH09KLTBL
AOH**K Multi
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.20 | 3.80 | -15° | 5.00 | 4.30 | |
|
AOHG18KBTB/ARXG18KLLAP
ARH**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
AOHG18KBTB/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.45 | -15° | 5.20 | 4.40 | |
|
AOHG14KGCB/ASHG14KGTF
ASH**K
|
GENERAL | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
AOHG12KBTB/AUXG12KVLA
AUH**K
|
GENERAL | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG14KGCA/ASHG14KGTE
ASH**K
|
GENERAL | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.50 | 4.00 | -15° | 4.20 | 4.00 | |
|
AOHG14KBTB/AUXG14KVLA
AUH**K
|
GENERAL | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG12KMCEN/ASHG12KMCEN
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG18KBTB/AUXG18KRLB
AUH**K
|
GENERAL | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.80 | -15° | 5.20 | 4.40 | |
|
AOHG12KBTB/ARXG12KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.10 | -15° | 3.50 | 3.40 | |
|
AOHG18KBTB/ARXG18KHTAP
ARH**K
|
GENERAL | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 |