Filters · 5 active
Manufacturer:
BOSCH
GENERAL
Vulcano
YORK
AIRCLASS
(1)
AIRWELL
(21)
ATLANTIC
(9)
AUX
(21)
BRYANT
(1)
Buderus
(8)
CARRIER
(42)
CIAT
(11)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(170)
EQUATION
(0)
FUJI ELECTRIC
(38)
FUJITSU
(102)
Fujitsu Atlantic
(48)
GREE
(45)
GSS
(1)
HAIER
(142)
HEC
(1)
HEIWA
(3)
HISENSE
(84)
HITACHI
(26)
IVT
(6)
Inventor
(27)
KAYSUN
(9)
LG
(75)
MIDEA
(171)
MITSUBISHI ELECTRIC
(131)
Mitsubishi Heavy Industries
(36)
NORD
(17)
Nobu
(2)
PANASONIC
(94)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(46)
THERMOR
(14)
TOSHIBA
(77)
Viessmann
(5)
WESTPOINT
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHG14KATA/ARXG14KLLAP
ARXG**K
|
GENERAL | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
YHKF18YEEGXFO-X/YHKF18XEEGXF-RX
Altair YHKF
|
YORK | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.70 | 4.00 | 3.71 | -10° | 5.10 | 3.30 | |
|
AOHG22KATA/ARXG22KMLA
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/ARXG22KMLB
ARXG**K
|
GENERAL | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/AUXG18KVLA
AUXG**K
|
GENERAL | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOHG22KATA/AUXG22KVLA
AUXG**K
|
GENERAL | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/ARXG18KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
AOHG14KATA/AUXG14KVLA
AUXG**K
|
GENERAL | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KBTB/ARXG14KLLAP
ARH**K
|
GENERAL | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
YHKF18XEEBMH-RY / YHKF18YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.65 | -10° | 5.30 | 4.10 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
YUKF18BYEEBMO-1/YKKF18BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG22KATA/ARXH22KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.55 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-X/YHKF18XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-T/YHKF18XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AOHG14KVCA/AGHG14KVCA
AGH**K
|
GENERAL | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
AOHG22KATA/AUXG22KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AOHG18KATA/AUXG18KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOHG14KETA /ASHG14KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA /ASHG14KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETE
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETE-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KMCC/ASHG14KMCF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETF
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KETA/ASHG14KETF-B
ASH**K
|
GENERAL | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
AOHH14KMCG/ASHH14KMCG
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCG-B
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCH-B
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHH14KMCG/ASHH14KMCH
ASH**K
|
GENERAL | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.10 | 3.83 | -15° | 4.20 | 4.00 | |
|
AOHG14KBTB/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG12KBTB/ARXG12KLLAP
ARH**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
CL6102i 55 HE / CL6102i W 55 HE
Climate 6102i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 |